background image

S

afety Instructions

 

 

 
 
 

 
Warning and Information labels 

The following listing details labels used on your AD Nano 
unit. 
 

Goggles, Gloves & Mask Label 

 
 
 

 

Location: Front face of filter. 
Meaning: Goggles, Gloves and Masks should be worn while 
handling used filters. 
 

Do Not Cover Label

 

 
 
 
 

Location: Rear Exhaust  
Meaning: Do not cover any louvers or holes adjacent to the 
label. 
 

Electrical Danger 

 
 
 

Location: Electrical access panel, top half of unit. 
Meaning: Removal of panels with this label attached will 
allow access to potentially live components. 
 

Warning Label 

 

Location: Next to release clips. 
Meaning: Power should be isolated before the panel with 
this label attached is opened/ removed. 
 

 
 
 
 
 

Serial Number Label 

 
 
Location:  Next to mains inlet. 
Meaning: This label contains a variety 
of information about the extraction 
unit, including: 

 

 

Company name, Address & Contact number 

 

Extractor model 

 

Unit serial number 

 

Operating voltage range 

 

Maximum current load 

 

Operating frequency 

 

Year of Manufacture 

 

Relevant approval markings/ logos 
 

PLEASE NOTE: 

If the equipment is used in a manner not 

specified by the manufacturer, the protection provided by 
the equipment maybe compromised. 

Fire Risk Warning 

In the very rare event that a burning ember or spark is drawn 
into the fume extraction unit, it may be possible that the 
filters will ignite.

 

Whilst any resultant fire would typically be retained within 
the fume extraction unit, the damage to the extractor would 
be significant. 

It is therefore essential to minimise this risk by undertaking 
an appropriate assessment to determine:- 

a). Whether additional fire protection equipment should be 
installed.  

b). Appropriate maintenance procedures to prevent the risk 
of build-up of debris which could potentially combust. 

This unit should not be used on processes where sparks 
could occur, with explosive dusts and gases, or with 
particulates which can be pyrophoric (can spontaneously 
ignite), without implementation of additional precautions.  

It is essential that nozzles or other extraction/ fume capture 
devices and hoses/pipework are cleaned regularly to prevent 
the build-up of potentially ignitable debris

 

02 

Summary of Contents for 30105519-1313

Page 1: ...AD Nano USER MANUAL V1 May 15...

Page 2: ...npacking and unit placement 3 01 02 Connecting to power supply Optional interfacing 4 01 Turning extractor on 5 01 02 Important safety notes Safety labels 2 01 02 Cleaning the unit Filter replacement...

Page 3: ...Overview Mains Isolation Switch Control Panel Lockable Castors Door Latches Combined Filter Combined Filter Lever Pre Filter 01 1...

Page 4: ...Overview Mains Inlet Signal Cable Inlet Optional Exhaust Outlet Air Outlet Air Inlet 02 1...

Page 5: ...Overview Main Isolation Switch Company Branding Filter Blocked Filter 75 full System Running Clean 03 1...

Page 6: ...moving the pump motor access panel 2 Use only as described in this manual 3 Connect the system to a properly grounded outlet Dangers to eyes breathing and skin Once used the filters within the AD Nano...

Page 7: ...acture Relevant approval markings logos PLEASE NOTE If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment maybe compromised Fire Risk Warning...

Page 8: ...t should be used and with regard to appropriate safety precautions See Appendix for product weight details Ensure that 500 mm space is available around any vented panels on the extractor to ensure ade...

Page 9: ...nit should not be connected to the mains The supply cord should only be replaced by a BOFA engineer as an electrical safety test may be required after replacement The AD Nano MUST be connected to a pr...

Page 10: ...PCB Red cable V Black cable V When the extractor is provided with the correct DC voltage the motor will start and maintain the set flow rate Refer to section 5 for how to set the flow when the DC volt...

Page 11: ...images below to identify the switch your AD Nano unit uses Powder Coated Version Press the main isolation switch to the On position Refer to section 1 for switch location by depressing the I side of t...

Page 12: ...prevent build up of dust and overheating of the unit Filter Information A log of filter changes should be maintained by the user The filters require attention when the display shows the configuration...

Page 13: ...orn when changing filters To remove and replace the pre filter follow the procedure detailed below 1 Isolate the electrical supply to the unit 2 Open the door of the unit 3 Remove the lower pre filter...

Page 14: ...tured from non toxic materials Filters are not re usable cleaning used filters is not recommended The method of disposal of the used filters depends on the material deposited on them For your guidance...

Page 15: ...l Below 60dB A at typical operating speed Size Metric mm Imperial inches Height 797 31 4 Depth 435 17 2 Width 377 14 9 Filters Filter Type Surface area Weight Efficiency Pre Filter 6 0 m F8 Combined F...

Page 16: ...Creekmoor industrial Estate Poole Dorset BH17 7DU UK Phone 44 0 1202 699 444 BOFA Americas 303 S Madison Street Staunton Illnois 62088 USA Phone 1 618 205 5007 BOFA International GmbH Sudring 62 D 21...

Reviews: