Installation, Operation and Maintenance manual
25
Downflo
®
Evolution
air regulator*
bleed-type air filter*
automatic condesate valve*
compressed-air
supply*
shut-off valve/safety exhaust valve*
*customer supplied
Turn power off and lock out electrical power sources.
Turn compressed-air supply OFF, bleed and lock out
lines before performing service or maintenance work.
Figure 13: Compressed air and component installation
Electrical connection
Amperage and voltage information is shown on the nameplate ratings of the
fan motor. Over amperage of manufacturer’s recommended service of motor
will cause damage.
•
If the fan is not premounted, connect the fan motor to the control box
according wiring diagram.
•
Connect the main power to the control box according the wiring diagram
included in the control box.
Check the rotation of the fan wheel (direction of the arrow on the fan housing).
If the fan is running in the wrong way, it will deliver only approximately 40%
of its rated air volume.
Lock out all electrical input power and interchange any two wire leads (3 phase
only) on the output side of the motor starter to reverse fan rotation.
Solenoid valves
See C-series controller manual.