Installation, Operation and Maintenance manual
25
WSO Flex
2. Wire the supply cable inside the unit using glands at the back of the unit and the
gland inside the controller back plate and connect phases and PE of the supply
cable to the controller panel with mentioned terminals in the allocation plan
(16, 17, 18 and 14).
Take caution that during installation the supply cable is not connected to
the electric net supply.
3. Connect DP tubes from the DP couplings in the controller back plate to the 2
DP sensors on the controller panel. DP1 is the sensor for the MAIN DP coupling
and DP2 is the sensor for the HEPA DP coupling. Double-check the DP tubes are
connected to the correct gland (one tube connected to HEPA (if HEPA is present),
others connected to MAIN) inside the unit.
MAIN
HEPA
4. Once everything is connected securely and double-checked, mount the controller
onto the unit with the delivered bolts.