16
8. To remove wind guide assembly.
1) Remove a screw for earthing.
2) Remove the noise filter from the wind Guide.
3) Remove a screw which secure the wind guide assembly.
4) Draw forward the wind guide assembly.
5) Pull the fan from the motor shaft.
6) Remove two screws which secure the motor shaded pole.
7) Remove the motor shaded pole.
8) Reverse the above steps for reasembly.
9. To remove H.V.transformer.
1) Remove four screws holding the H.V.transformer.
2) Remove the H.V.transformer.
3) Reverse the above steps for reassembly.
Summary of Contents for KOR-164H0W
Page 5: ...5 EXTERNAL VIEW 1 OUTER DIMENSION ...
Page 25: ...25 WIRING DIAGRAM ...
Page 27: ...27 Measure Point MP1 GND MP2 ...
Page 29: ...29 2 PCB CIRCUIT DIAGRAM ...