20
CONDITION
CHECK
Check continuity of high
voltage fuse
RESULT
No
Continuity
Check continuity if high
voltage capacitor terminals
with wires removed
Replace high voltage fuse
Continuity
CAUSE
Defective high
voltage
transformer
REMEDY
Replace
No
microwave
oscillation
Check continuity of high voltage
rectifier in forward and backward
direction with DC megger
Continuity in
backward
direction
Defective high
voltage rectifier
Replace
Connect megger leads to
magnetron terminal and
magnetron body
Continuity
Defective
magnetron
Replace
Check resistance of primary and
secondary coil of high voltage
transformer
0
Ω
or
∞
Defective high
voltage
transformer
Replace
Check continuity of magnetron
with wires removed
No
Continuity
Defective
magnetron
Replace
Check continuity of filament
terminal of high voltage
transformer
No
Continuity
Defective high
voltage
transformer
Replace
Check D.C. voltage being
supplied to RELAY (RY1) coil
0 V
Defective touch
control circuit
Replace
Approx
15 VDC
Faulty
contacts or
RELAY (RY1)
or open
relay coil
Replace
(TROUBLE 3)
No microwave oscillation even though fan motor rotates.
Summary of Contents for KOR-164H0W
Page 5: ...5 EXTERNAL VIEW 1 OUTER DIMENSION ...
Page 25: ...25 WIRING DIAGRAM ...
Page 27: ...27 Measure Point MP1 GND MP2 ...
Page 29: ...29 2 PCB CIRCUIT DIAGRAM ...