5. How To Charge R-600a Refrigerant
NO.
SVC process
Image
Details
1. Conect can adapter to the coupling pipe.
2. Charge the ref. with open lever slowly.
※
Refrigerant should never leak in the room.
1. On the power of refrigerator and then
start to charge the ref. (10min)
※
Charge the ref. until going out the water
vapour condensing on the can outlet.
1. Check the leakage.
※
You must rework from Step.1
when the leakage is detected.
1. Clean and clear around the machinery
room when the service is finished.
2. Assemble the machinery room cover.
17
Finish
14
Connecting of
coupling pipe
&
adapta
15
Charging
16
Leakage Test
28