background image

Parts and Function

The 595A audio door panel is designed for all DT 2-wire systems.
The front panel is made of zinc alloy for better protection against vandalism & cauterization, and 
the call button is also made of zinc alloy with blue backlight for auxiliary illumination, the unlock 
and talking LED indicator ensures the door panel is working efficiently.
With the rain cover, the door panel is strongly protected against the rain. 

◆ 

Lock Control Jumper:

 

to select the lock type. Please refer to Electric Lock Connection

◆ 

DIP switch:

 to set ID code for the door panel, total of 4 door panels can be connected. 

Please  refer to DIP Switch Settings for additional door panels.

◆ 

SPK adjust: 

to adjust the talk volume.

◆ 

PROG button: 

reserved.

◆ 

CALL button: 

press to call the user.

◆ 

4P terminal: 

to update software via specified programmer. (Manufacturer only)

◆ 

Connection line:

 to connect the bus line and the electronic locks.

      BUS (Blue&Green): 

connect to the bus line, non polarity.

      S2+(Red): the S2+ connect with S1- to activate the relay of ERL to extend a camera of DT-CAM, 

Unit Mounting

The location of the door panel should be kept away from direct weather and all intensity light.

Accessory contents:

Accessories include a screwdriver T20, one M4X10 screw,  two PA4X25 screws, three PA3x25 
screws, three PM3x12 screws and five screw stoppers 6X30.

Installation steps:

Installation height for the door panel is typically 145-160cm.
1. Use screws to fix the back panel and rain cover to the wall, then connect the cable correctly.
2. Attach the front panel to the back panel, then use the screw to fix it.

Wiring and Connection

Basic one-to-one connection

Terminal Description

Speaker

Talk Indicator

Unlock Indicator

Call Button

Front Panel

Microphone

1

2

3

4

7

5

6

1

2

3

4

5

6

Rain Cover

7

M4*10

PM3*12

1

2

3

BUS(Blue&Green);

   S2+(Red);   PL(White);   S1+(Yellow);   S1-(Black);

1 2 3

ON

1  2  3

1 2 3

ON

1  2  3

BUS(Blue&Green)
S2+(Red)
PL(White)

S1+(Yellow)
S1-(Black)

4P

terminal

DIP

PROG

SPK adjust

Lock Control

Jumper

Connection line

CALL button

please refer to DT-CAM user instructions for details (Not available from Doorentryonline Ltd)

PL(White): external lock power input, connect to the power positive (power +).

S1+(Yellow): lock power(+) output.

S1-(Black): lock power(-) output.

-

+

AC~

Handset

DPS

PS4

L1  L2  PL  S1+  S2+  S-

-3-

Doorentryonline 

Ltd

Summary of Contents for DT595A

Page 1: ...DT595A USER MANUAL 2 Wire Audio Entry System Read this manual carefully before using the product and keep it safe for future use D o o r e n t r y o n l i n e L t d...

Page 2: ...be connected Please refer to DIP Switch Settings for additional door panels SPK adjust to adjust the talk volume PROG button reserved CALL button press to call the user 4P terminal to update software...

Page 3: ...o fix the back panel and rain cover to the wall then connect the cable correctly 2 Attach the front panel to the back panel then use the screw to fix it Wiring and Connection Basic one to one connecti...

Page 4: ...L2 PL S1 S2 S L1 L2 PL S1 S2 S 1 2 ON 1 2 ON 1 2 ON 1 2 ON 1 Panel DIP on off off ID 00 ID 10 ID 01 ID 11 2 Panel 3 Panel 4 Panel DBC4S A B C D OFF ON Impedance switch Code 0 DIP 6 off 1 2 3 4 5 6 ON...

Page 5: ...e 4 DIP 6 on 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON Code 3 DIP 6 on Code 1 DIP 6 on 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON Code 2 DIP 6 on Code 0 DIP 6 on OFF ON OFF ON monitor 1 monitor 3 monitor 5 monitor 7 monitor 8...

Page 6: ...LOCK Jumper position in Connect one lock 2 3 Bus PL S2 S1 S1 Note 1 The external power supply must be used according to the lock 2 The jumper must be taken off before connecting 3 Setup the Unlock Mod...

Page 7: ...nstallation There are 6 bits in total The DIP switches are used to configure the user code for Monitors Bit 6 is an video impedance match switch which have to be set to ON if match the impedance other...

Page 8: ...se use a small amount of pure water or diluted soap water to clean the unit The unit is weather resistant however do not spray high pressure water on the access control keypad directly Excessive moist...

Page 9: ...y also affect the maximum distance which the system can reach Cable Usage A B C Twisted cable 2x0 75 mm2 60 60 30 80 80 40 Twisted cable 2x1 mm2 Cable Usage A B C Twisted cable 2x1 mm2 70 30 20 70 50...

Reviews: