suPPLEmEnt
Dismounting
unplug the electric drive . dismount the
electric drive according to the directions
for electric drive . close the door and loose
the spring . then dismounting must be
performed in accordance with this directions
in the reverse order .
Upgrading
I
nstallation of the additional equipment
or accessories as well as self-replacement
or self-adjustment of the components
without consulting with the manufacturer is
forbidden .
only original spare parts and accessories
are recommended to be applied for installation
and operation of the sectional doors .
the manufacturing company shall not
be held responsible for possible injuries and
wrong done to people, animals or objects in
case of unauthorized modification
.
Maintenance
The sectional doors do not need any
com
plicated or special maintenance .
Panels that make up the door shield, have
the resistant protective-decorative coating .
to keep them nice and tidy we recommend
to clean their surface using a moist rag and
neutral domestic detergents .
in case of door hinge creaking or roller
axes creaking they should be lubricated
through the lubrication hole in the central
part of the hinge curl or in the central part of
the roller holder curl .
if closing or opening of the doors
requires force applying, adjust the rollers .
if there is a clearance between the roller and
the track profile, loose the bolts on the roller
holder, move the roller holder along the slots
until the roller fits tightly to the track, tighten
the loosed bolts on the roller holders .
if there are creaks and knocks in the
torsion gears clean them from dust and dirt
with a dry rag and streak any lubricant for
metal surfaces on the about 3 cm wide area
along the spring
for manual opening and closing of the
door the handle is used .
if the automatic drive is used follow the
directions for the drive .
do keep the tracks clean . do not apply
lubricants for them!
after about 20000 times of door
operation acts an expert should test the
spring mechanisms .
test is carried out by the doors operation
intensity:
·
up to 5 times a day – every 9 years;
·
up to 10 times a day – every 4 .5 years;
·
up to 20 times a day – every 2 .5 years;
·
up to 50 times a day – every year .
the doors should be installed, adjusted or
repaired only by qualified specialists .