1. SETTINGS
The radio code Key Pad is compatible with built-in and external DoorHan
receivers and used for remote control of electronic devices. Radio
commands may be given only after a sequence of numbers from 0 to 9,
which is an access code (PIN), is entered, factory preset is «0000». If the
sequence is right, the keypad will produce short sound. Now you may use
2 different radio channels to control 2 different devices. After pushing any
key you will hear short sound. After first pushing a key the keyboard will
actuate for 3 sec, (LEDs will light), within this time you can enter PIN code
for control of electronic device. When this time is up, the keypad will be
off (LEDS will go out) and to activate the keypad again, you will have to
push the key again. The system allows pushing the keys 8 times maximum
before it activates the guard status for 3 min. When guard status is active
you may not enter the code and every pushing the keys will produce error
signal (4 successive sounds). The PIN code may be re-entered only after 3
min.
IMPORTANT: After you change the factory preset PIN code for an individual
one, we recommend you to write down your new PIN code and save it for
emergency use.
2. TECNICAL DATA
Then inter the code and
press key «*» or «#»
3. INSTALLATION
1. Remove the button panel with a screw driver.
2. Screw out the screws and remove the upper housing and the button sheet.
3. Put the base housing against the selected location on the wall and make
marks in 4 places on the wall though the installation holes with a pencil.
4. Install the base housing to the wall. Reinstall the button sheet and the
upper housing, and screw it securely to the base housing. To avoid cracking
the plastic housing, do not over tighten.
5. Reinstall the button panel to the upper housing putting the locking pins of
the upper cover into the holes of the bottom plate, then push the upper side
of the cover to lock with the bottom plate.
4. PROGRAMMING
1. Change PIN code (plant mounting «0000»)
Push «*» and «#» at the same time and hold them during 5 sec., LEDs begin to
blink. Enter the old PIN code and push «#».
LEDs begin to blink faster, enter the new PIN code from 1 to 8 figures and
push «#». LEDs will flash permanently, but after some period will blow out.
PIN code was changed.
2. Delete all codes (renew plant mounting)
Push «*» and «#» at the same time and hold them during 5 sec., l LEDs begin
to blink, push and hold SW1 button at the reverse side of plate until the
LEDs will blow down. PIN code was renewed on plant mounting.
5. PROGRAMMING CODE FOR RECEIVERS
It is possible to record two different codes for keypad: into internal receiver
DoorHan, which is used for Sectional motors, and external receiver DHRE-2.
To record the code of key-pad into internal receiver DoorHan it is necessary:
In order to record the radio code numeric pad into external DHRE - 2 receiver,
do the following: Connect electric operator control contacts to outputs of
radio receiver. To record PIN code of a keypad (button *), press button SW1
(code record), at that indicator LED1 on the receiver will light up. After that
enter PIN code and press the *. To record PIN code of a keypad (button #),
press button SW2 (code record), at that indicator LED1 on the receiver will
light up. After that enter PIN code and press the #. To clean receiver memory,
press and hold down button SW1 or SW2 respectively.
Note: To control the first device, enter the PIN code on the keypad and press
button *. To control the second device, enter PIN code on the keypad and
press button #. (PIN code for control of the first and second devices is the
same).
Friquency
443 Мгц
Battery
2x3V CR2032
Current
<2
µ
A
Class IP
IP54
Temperature range
-40
0
С +50
0
С
Installation type
On the surface
EC DECLARATION OF CONFORMITY
We: DoorHan Europe s.r.o.
Bozeny Nemcove 1689, 43201 Kadan, Ceska Respublika Herewith declare
under sole responsibility that:
• Declares that:
The device model Keypad
•
complies with the essential safety requirements of the
following directives:
73/23/EEC and subsequent amendment 93/68/EEC
89/336/EEC and subsequent amendment 92/31/EEC and
93/68/EEC
A dditional note:
These products have undergone tests in a typical uniform configuration
(all products manufactured by DoorHan Europe s.r.o.)
01/03/2010 Mikhail Kiselev Managing Director
Date signature
INSTALLATION MANUAL REYPAD
Sw1