2.2 High Voltage Terminal Connection
Use the existing wire restrainers
inside operator to keep wire
away from moving parts.
A
separate
power disconnect
switch may be needed in your
area. Check local building
codes before installation.
Note:
“Optional”
High Voltage Kit
black and white wires
connect the same as
shown above.
115 VAC
AC Power Terminal
Chassis Ground
White - Neutral
Black - 115 VAC Hot
Green - Chassis
Ground
DANGER
DANGER
HIGH VOLTAGE
•
Route incoming AC power wire through the high voltage conduit and run wire in the operator as shown.
•
Be sure wiring is installed in accordance with local codes. Be sure to color code all wiring.
•
It is recommended that a surge suppressor be installed on the high voltage power lines to help protect the operator
and circuit board from surges and power fluctuations.
•
Dual operators (Primary/Secondary) require AC power to each operator.
Hot
Neu
Loosen the 2 nuts
under the electronic box
to swing box up.
DO NOT
power up and cycle the
operator until the “
Physical stops”
have been installed.
Damage could
occur to the gate and
operator.
High Voltage
AC Power Wire
External Power
Disconnect Switch
MOV
- Helps protect operator
from power surges.
AC Power
AC Power
Dual Operators
Every time
the 9150 is powered up, the
First
open command will automatically run “
Multiple
gate cycles”
that will locate and remember the gate’s open and close positions (See page 23).
AC POWER
ON
OFF
High
Voltage
Conduit
EXTERNAL ENTRAPMENT PROTECTION DEVICES MUST be connected
or the gate operator WILL NOT function. (See pages 25-29)