3.1 4602 Circuit Board Description and Adjustments
SECTION 3 - ADJUSTMENTS
The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is
complete.
Whenever any of the programming switches on the circuit board are changed, power must be shut-off, and then
turned back on for the new setting to take effect. Every time
the 9150 is powered up, the
First
open command will automati-
cally run “
Multiple gate cycles”
that will locate and remember the gate’s open and close positions (See page 23).
Auto-close timer (when
turned on) SW 1, switch 2.
Adjust from 1 second
(full counter clockwise) to
approximately 23 seconds
(full clockwise).
Dry relay contacts
(terminals 15-16) can be
set for Normally Open
(NO) or Normally Closed
(NC) operation by placing
the relay shorting bar on the
N.O. or N.C. pins respectively.
SW 1, switches 4 and 5 must
be set to control relay. See
next page for descriptions.
1
23
Auto-Close Timer
Dual Channel Loop Detector
Single Channel Loop Detector
Dry Relay Contact
NC
NO
Set the DIP-switches
on the circuit board
to the desired
setting. See switch
setting charts on
next 2 pages.
DIP-Switches
ON
1
2
345678
SW 2
ON
1
2
345678
SW 1
ON
1
2
345678
SW 1
LEDs
Indicates that low voltage power is applied to the circuit board.
Input LEDs
should be OFF
and will only illuminate when the input is activated.
Pulse LEDs
will blink as the operator is running.
They can be either ON or OFF when the operator is stopped.
Full Open
Fire Dept Open
Adjust reversing sensitivity.
Full counter clockwise for
minimum sensitivity, full
clockwise for maximum
sensitivity. See page 24.
Min
Max
Sensitivity
Inherent Reverse Sensor
2
3
4
5
11
UL 325
Terminal
Pages 25-29
UL 325
DIP-Switches
Pages 25-29
S
3-Button Control
Station Jumper
Page 32
Power LED
Pulse LEDs
Input LEDs
UL 325 LEDs
Magnetic
Sensors
See page 24.
Alarm Plug
MUST
be
plugged in.
ON
12
3
45
678
SW 1
Typical Settings
Exit Loop Port
Reverse Loop Port
See page 30.
See page 34.
Cycles the operator when
pressed. Gate opens to full
open position ONLY. It will use the
Auto-Close timer when turned ON.
Connect
ONLY
emergency access
controls accessible by authorized
personnel (e.g., fire, police, EMS).
Upon activation, alarm will sound
and the operator will go into a
hard shutdown
after reaching the
open limit. Operator must be
reset to resume normal operation.
See pages 32, 36-37.