9150-065-Y-12-20
21
7-OFF
7-OFF
7-ON
7-ON
8-OFF
8-ON
8-OFF
8-ON
Gate
Open
Back-Off
Position
Normal Setting.
Gate fully opens.
Gate stops short 1” from full open position. Used for a reversing edge device.
Gate stops short 2” from full open position. Used for a reversing edge device.
Gate stops short 3” from full open position. Used for a reversing edge device.
3.2 DIP-Switch SW 1 and SW 2 Settings
The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on
or off various operating features. Whenever a switch setting is changed, power to the operator must be turned OFF and then
turned back on for the new setting to take affect. Check and review ALL switch settings prior to applying power to the operator.
SW 1 Switch 1
Must OPEN
the gate upon initial AC power up and open command. If the first open command begins to close the
gate, turn AC power off and reverse this switch. Opening direction will vary depending on the type of installation (See above).
SW 1 Switch 2
Turns the auto-close timer on or off. Can be adjusted from 1 to 23 seconds to close gate.
SW 1 Switch 3
This switch should be left in the OFF position when the slide gate is running on a level track and the gate does not
coast after it has stopped. If the gate is on an incline, turning this switch on will apply a small DC voltage to the motor windings
after the gate has stopped. This applies braking power to the motor to prevent the gate from “coasting” after it has stopped.
SW 1 Switches 4-5
These work in conjunction with each other and determine when the relay on the board will be activated. This
relay can be used as a switch for various functions such as illuminating a warning light when the gate is moving, or turning on a
green light when the gate is full open. If a magnetic lock is used with the gate operator, these switches must be set for magnetic
lock operation which limits the relay to activate only when the gate is opening and full open.
SW 1 Switch 6
Leave this switch OFF.
SW 1 Switches 7-8
These work in conjunction with each other and determine if the operator will stop the gate at the full open
position, or if the gate should stop 1, 2 or 3 inches short of the full open position. Needed only when using a reversing edge
entrapment protection device on the
opening
edge of the gate with an end post as the physical stop.
Switch
Function
Setting
Description
SW 1 (Left 8 Switches)
OFF
ON
4-OFF
4-OFF
4-ON
4-ON
5-OFF
5-ON
5-OFF
5-ON
Auto-Close
Timer
Relay Activation
and
LED Indicator
Light Activation
2
1
Motor
Hold
OFF
ON
3
4 and 5
7 and 8
Normal Setting.
No voltage to motor when gate is stopped (Level gate).
Voltage applied to motor always. Keeps inclined gate from coasting when stopped.
Auto-close timer is OFF. Manual input required to close gate.
Auto-close timer is ON. Adjustable from 1-23 seconds to close gate.
OFF
Not Used
6
Leave on OFF settng.
Relay activates and LED is ON when the gate is fully open.
Relay activates and LED is ON when the gate is not closed.
Relay activates and LED is ON when the gate is opening and open.
Relay activates and LED is ON when the gate is opening and closing.
Every time
the operator is powered up, the
First
open command will automatically run “
Multiple
gate cycles”
that will locate and remember the gate’s open and close positions (See page 23).
Changes the direction the operator will open/close the gate depending on the different chain configurations.
Opening
direction
using
OFF
setting.
Opening
direction
using
ON
setting.
Post
Mounts
Center or
Opens
with
ON
setting.
Mounts
Right
All Rear
Opens
with
OFF
setting.
Mounts
Left
All Rear
Opening
direction
using
ON
setting.
Opening
direction
using
OFF
setting.
Mount
Front