9150-065-Y-12-20
2
5
ON
ON
REVERSE
SENSITIVITY
REVERSE
LOOP
EXIT
LOOP
FULL OPEN
DOORKING
4602-018
SW1
SW3
SW2
OPEN
TIMER
NC
NO
1
2
3
4
5
6
7
8
9
10
1
ON
2
3
4
1
ENABLE STOP
SHORT PINS 1&2
2
3
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
ON
2
3
4
1
ENABLE STOP
SHORT PINS 1&2
2
3
FIRE
7
OPEN Edge:
Obstructed reversing edge will reverse the gate
to the close position
during the opening-direction only.
•
After the gate reverses to the close position, any opening
input will cycle the gate again.
Note:
If the gate is opening by a time clock and the edge
gets obstructed, the gate will return to the closed position and
another input (automatic exit loop, reverse loop, remote etc.)
is needed to cycle the gate open again.
UL 325 Terminal and LEDs
Connect
ONLY MONITORED
Devices
UL 325 DIP-Switches
115 VAC
Convenience
Outlets
1 - OPEN Beam (Switch 1)
2 - Ground (Common)
3 - CLOSE Beam (Switch 2)
4 - Ground (Common)
5 - 24 VAC 250 mA Max (don’t exceed this)
6 - Ground (Common)
7 - OPEN Edge (Switch 3)
8 - Ground (Common)
9 - CLOSE Edge (Switch 4)
10 - Ground (Common)
1 - OPEN Beam
2 - CLOSE Beam
3 - OPEN Edge
4 - CLOSE Edge
SECTION 4 - ENTRAPMENT AND SAFETY PROTECTION
4.1 UL 325 Description
Closed Gate
Wall / Fence
Filler Post if necessary
Closed Gate
Wall / Fence
Closed Gate
Wall / Fence
CLOSE Beam:
Obstructed closing-direction photo beam
will reverse the gate to the open position and reset the
close-timer
during the closing-direction only.
Gate will close when timer times out.
Closed Gate
Ground (Common):
Common terminal for all MONITORED entrapment protection device inputs.
1
3
OPEN Beam:
Obstructed opening-direction photo beam
will stop the gate
during the opening-direction only.
Gate
will resume the open cycle when the obstructed photo beam
has been cleared.
Open Edge - Wireless
Open Edge
Wireless - Close Edge
Entrapment Area
Entrapment Area
Entrapment Area
Entrapment Area
W
ARNING
MOVI
NG
GA
TE C
AN
CA
US
E
Op
era
te g
ate
on
ly w
hen
ga
te a
rea
is i
n s
igh
t
and
fre
e o
f pe
op
le a
nd o
bstr
ucti
ons
.
Do
no
t a
llow
ch
ildr
en to
pla
y in
ga
te a
rea
or o
per
ate
ga
te.
Do
no
t sta
nd in
ga
te p
ath
or
wa
lk th
rou
gh
path
w
hile
ga
te is
m
ovin
g.
Rea
d o
wn
er’s
m
anu
al a
nd s
afe
ty in
stru
ctio
ns.
SE
RIO
US IN
JU
RY
OR
DE
AT
H
CLA
SS
CER
TIFI
ED
TO
CA
N/C
SA
C2
2.2
NO
. 2
47
CO
NF
OR
MS
TO
AN
SI/U
L-3
25
VEH
ICU
LA
R G
ATE
O
PER
ATO
R
HP
533
82
MO
DE
L
SER
IAL
VO
LTS
PH
ASE
AM
PS
60 H
z
MA
X G
ATE
LO
AD
Doo
rKin
g,
Inc
., In
gle
wo
od,
CA
ON
ON
RE
VE
RS
E
SE
NS
ITIV
ITY
RE
VE
RS
E
LO
OP
EX
IT
LOOP
KEY
SW
ITCH
DOOR
KI
NG
46
02
-0
10
SW
1
SW2
OP
EN
TIM
ER
NC
1
2
3
4
5
NO
UL 325 LEDs:
LED ON:
Connected device has been activated.
LED remains off during normal operation.
LED Flashing:
Connected device is in fault.
Wiring to device is bad.
2, 4, 6, 8 & 10
DIP-switches
MUST
be turned
ON
for
each device wired to
terminal.
Monitored Device Note:
Only 1 monitored Device can be
connected to each input. An
OPTIONAL
Expansion Board
(sold separately) will allow connection for additional devices.
UL 325 Terminal #5 Note:
Exceeding 250 mA of power from this terminal
may cause the circuit board transformer to
overheat, causing intermittent problems.
Open Beam
Open Beam
Close Beam
Wall / Fence
Filler Post if necessary
Typical Open Beam Locations
External Entrapment Protection Devices:
In addition to the inherent reversing sensor system, this operator has a UL 325 terminal for the connection of
photo sensors
-Type B1 and/or
reversing edges
-Type B2 entrapment protection required by UL 325 standards. Install these devices where the risk of entrapment or a safety
hazard exists, examples of which are shown below and the next 4 pages. Installations can vary.
Entrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists. The operator will NOT
run without ONE or more monitored type B1 or B2 external entrapment protection devices installed in EACH direction of gate travel
(minimum of 2 external devices required).
CLOSE Edge:
Obstructed reversing edge will reverse the gate
to the open position
during the closing-direction only.
•
After the gate reverses to the open position, the close-timer
will time out and close the gate (if it is turned on).
•
If a second sequential obstruction is encountered prior to the
gate reaching the close limit, the gate will
reverse to full open
position
and enter a soft shutdown condition (See page 35).
9
Typical Open Edge Locations
Device Terminal Number/Function and General Location