9150-065-Y-12-20
4
WARNING
MOVING GATE CAN CAUSE
Operate gate only when gate area is in sight
and free of people and obstructions.
Do not allow children to play in gate area
or operate gate.
Do not stand in gate path or walk through
path while gate is moving.
Read owner’s manual and safety instructions.
SERIOUS INJURY OR DEATH
CLASS
CERTIFIED TO
CAN/CSA C22.2 NO. 247
CONFORMS TO
ANSI/UL-325
VEHICULAR GATE OPERATOR
HP
53382
MODEL
SERIAL
VOLTS
PHASE
AMPS
60 Hz
MAX GATE LOAD
DoorKing, Inc., Inglewood, CA
15.25”
16.75”
17.75”
24.75”
Gate Frame
Class of Operation
Model 9150 - UL 325 Class I, II, III, IV
Type of Gate
Vehicular Slide Gates Only
Drive Sprocket Size
#40
Chain
Cycles Per Hour
60 Per Hour (Installed level).
Speed
Approximately 1 Ft. per Second (Installed level).
Inherent Entrapment Protection Device
Inherent Reverse Sensor System (Type A)
External Entrapment Protection Device Inputs
Connection inputs for Non-contact Sensor - Photo Sensor (Type B1)
(Monitored Inputs)
Connection input for Contact Sensor - Reversing Edge (Type B2)
SPECIFICATIONS
4” Minimum
1” Minimum
10.5”
Use this manual for the Model 9150 operator with circuit board 4602-018 Rev A or higher ONLY.
Chain Height:
Idler wheels in
top position.
Concrete
Pad
Concrete
Pad
Operator
Specification
Decal
DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons
of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights
reserved. No portion of this manual may be copied, reproduced, translated, or reduced to any electronic medium without prior written consent from DoorKing, Inc.
Gate installed level and in good working condition
Note:
208/230/460/575 VAC input voltage can be connected to the
operator by installing an “Optional” High Voltage Kit (P/N 2600-266).
Model #
Cover Type
Max Gate
Weight
Max Gate
Length
Horsepower
- Volts
1/2 HP - 115 VAC
1 HP
- 115 VAC
1/2 HP - 115 VAC
1 HP
- 115 VAC
1ø
1ø
1ø
1ø
9150-384
9150-380
9150-386
9150-385
Metal
Metal
Polypropylene
Polypropylene
1,000 Lbs.
1,500 Lbs.
1,000 Lbs.
1,500 Lbs.
30 Ft.
45 Ft.
30 Ft.
45 Ft.
Amp
Phase (Ø)
5.4
9.7
5.4
9.7
Entrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists.
The operator will NOT run without one or more monitored type B1 or B2 external entrapment protection devices
in EACH direction of gate travel (minimum of 2 external devices required).
Type of wiring to be used on ALL
external devices:
A)
Type
CL2
,
CL2P
,
CL2R
, or
CL2X
.
B)
Other cable with
equivalent
or
better
electrical, mechanical, and
flammability ratings.
Polypropylene Cover Note:
Allows
wireless signal through cover.
Metal Cover