DOOR OPERATION
13
I
USER MANUAL
EXIT AND ENTRANCE INTO THE BUILDING
The following exit or entrance procedures can be used if automatic sliding doors product line 300 are
installed at the entrance of a building, which is also the only entrance:
1.
EXIT from the building:
a)
“EXIT SUMMER” or “EXIT WINTER” operating mode: The doors will normally open
at the exit with exit sensor .
b)
“LOCK” operating mode: The function “SINGLE EXIT” must be first enabled in the
system settings to allow one time exit from the building . The doors will open once
by activating the exit sensor for 120 seconds . After this time or with the activated
exit sensor, exit from the building via the sensor will no longer be possible .
2.
ENTRANCE into the building in “CLOSED”, “EXIT SUMMER” or “EXIT WINTER” operating
mode:
Entry into the building with the entry sensor is not possible . Install an additional switching
mechanism (card reader or other access control) connected to the input “
open once
” (X7-1)
on the door controller .
The energy save system shuts down the main power supply in the operating mode »CLOSED«, »OPEN«
and »STOP« and stays on battery power supply with reduced power consumption (less than 0 .5 W) .
The door leaves can be manually moved if the system is not equipped with the EL5 electric lock . Push the
WAKE BUTTON to wake up the doors from the energy save mode and then change the operating mode
into the preferred position . The system will shut down automatically again if the operating mode stays in
»CLOSED«, »OPEN« and »STOP« position .
Redundancy testing, door may open!
ENERGY SAVE