FIRST STARTUP
17
I
USER MANUAL
The following steps must be carried out before the first start-up:
1 .
The power supply plug must be pulled out;
2 .
The sliding leaf/leaves must be half open;
3 .
Check if the installation is in accordance with the installation manual;
4 .
All the mechanical safety elements and locking elements have to be unblocked and ensure
an uninterrupted initialization;
5 .
Switch on the system by plugging the power supply plug into door controller EC4;
6 .
Connect the battery unit BU3 with connector X4 on the door controller EC4 if the door
system comprises of a battery unit;
7 .
Switch the mode selector to the “AUTOMATIC-SUMMER” position;
8 .
The sliding leaf/leaves will slowly close;
9 .
The system will save the position CLOSED when the doors are closed (at the damper limit
in a one leaf door or when the leaves lean against each other in double leaf doors) .
10 .
The doors will then slowly move to an open position and the system will save the position
OPEN at the damper limit;
11 .
The system initialization is complete .
The cable installation for the power supply and connection to the door system may be carried
out only by a specially trained person and according to current regulations . The door
construction must be additionally grounded in the case that the automatic doors are installed
on a steel construction .
Power supply will be necessary for at least 24 hours from the first system start-up to fully
charge the battery unit BU3 .
Please unplug the battery unit BU3 from door controller EC4 (X4 connector) if the doors are not
used for one week or more . The battery can be stored for a maximum of half a year
DISCONNECTED .