OPERATING INSTRUCTIONS
15
7/124 - 10/104, 10/124 - 14/114, 14/84
COMMISSIONING
Upon receipt of the unit, and prior to putting it into service, it is
important to adhere strictly to the instructions given below in
PRIOR
TO STARTING
.
Ensure that the operator reads and
understands
the decals and
consults the manuals before maintenance or operation.
Ensure that the position of the
emergency stop
device is known and
recognised by its markings. Ensure that it is functioning correctly and
that the method of operation is known.
Before towing the unit, ensure that the tyre pressures are correct (refer
to the
GENERAL INFORMATION
section of this manual) and that the
handbrake is functioning correctly (refer to the
MAINTENANCE
section
of this manual). Before towing the unit during the hours of darkness,
ensure that the lights are functioning correctly (where fitted).
Ensure that all transport and packing materials are discarded.
Ensure that the correct fork lift truck slots or marked lifting / tie down
points are used whenever the machine is lifted or transported.
When selecting the working position of the machine ensure that there
is sufficient clearance for ventilation and exhaust requirements,
observing any specified minimum dimensions (to walls, floors etc.).
Adequate clearance needs to be allowed around and above the
machine to permit safe access for specified maintenance tasks.
Ensure that the machine is positioned securely and on a stable
foundation. Any risk of movement should be removed by suitable
means, especially to avoid strain on any rigid discharge piping.
Attach the battery cables to the battery(s) ensuring that they are
tightened securely. Attach the negative cable before attaching the
positive cable.
Lifting
The central lifting bail allows the compressor to be lifted from a single
point. Use hoist or crane capable of lifting compressor weight (See
General Data).
WARNING: All air pressure equipment installed in or connected
to the machine must have safe working pressure ratings of at
least the machine rated pressure, and materials compatible with
the compressor lubricant (refer to the
GENERAL INFORMATION
section).
WARNING: If more than one compressor is connected to one
common downstream plant, effective check valves and isolation
valves must be fitted and controlled by work procedures, so that
one machine cannot accidentally be pressurised / over
pressurised by another.
WARNING: If flexible discharge hoses are to carry more than 7
bar pressure then it is recommended that safety retaining wires
are used on the hoses.
WARNING: Falling off the compressor can cause serious injury
or death. Use ladder and hand holds to access lifting bail.
Summary of Contents for 10/104
Page 2: ......
Page 4: ......
Page 11: ...ISO SYMBOLS 7 7 124 10 104 10 124 14 114 14 84 Replace any cracked protective shield ...
Page 83: ...MAINTENANCE 79 7 124 10 104 10 124 14 114 14 84 ...
Page 84: ...80 MAINTENANCE 7 124 10 104 10 124 14 114 14 84 ...
Page 92: ...88 MACHINE SYSTEMS 7 124 10 104 10 124 14 114 14 84 ...
Page 108: ......
Page 109: ......