OPERATING INSTRUCTIONS
11
9/275, 9/305, 12/250, 17/240, 21/220
OPERATING CONTROLS AND INSTRUMENTS
The operating controls and instruments are arranged on the control
panel as shown above. A description of each panel device is as
follows:
1.
ViewPort:
Graphic display showing information about
performance parameters, warnings, faults, Maintenance Manual
and Parts Catalogue.
1A.
High Exhaust System Temperature (HEST) Lamp:
Illuminates
when exhaust temperatures are high due to regeneration of the
DPF.
1B.
Aftertreatment Diesel Particulate Filter (DPF) Lamp:
Illuminates when the DPF requires regeneration.
1C.
Regeneration Disabled Lamp:
Illuminates when regeneration is
disabled by the regeneration control switch.
1D.
Wait to Start Lamp:
Illuminates when the operator should wait
before starting the engine because the intake air heater is heating.
2.
Joystick:
Device to move in graphic menu.
3.
Main Control Switch:
Used for starting and stopping the
compressor.
3A.
OFF:
Stops the compressor.
3B.
ON:
Turns on compressor control system and ViewPort.
3C.
RUN:
Turns on engine control system.
3D.
START:
Initiates engine cranking. Momentary position.
4.
Service Air Switch:
Momentary contact switch. Allows engine to
warm up at low compressor pressure.
5.
Discharge Air Pressure Gauge:
Indicates pressure in receiver
tank, normally from 0 psi (kPa) to the rated pressure of the
machine.
6.
Engine Tachometer:
Indicates engine speed in RPM from 0
when stopped to full speed.
7.
Hourmeter:
Indicates machine operating hours.
8.
Compressor Oil Temp Gauge.
9.
Fuel Level Gauge:
Indicate fuel level in tank.
10.
Battery Voltage Gauge.
11.
Engine Water Temp Gauge.
12.
E-STOP:
Emergency Stop Push Button. Push to stop, turn to
release.
13.
Panel Light:
Illuminates the instrument control panel.
14. Position for optional switches.
15.
Regeneration Control Switch:
Provides operator control of the
exhaust aftertreatment regeneration.
15A.
Regeneration Initiate Position:
Requests manual (non-mission)
regeneration of DPF if entry conditions are within proper range.
Momentary position.
15B.
Normal Position:
Allows automatic regeneration of DPF to take
place as needed.
15C.
Regeneration Disable Position:
Inhibits automatic and manual
regeneration of DPF.