OPERATING INSTRUCTIONS
21
9/275, 9/305, 12/250, 17/240, 21/220
J1939
SPN
J1939
FMI
CUMMINS
CODE
J1939 SPN DESCRIPTION
J1939 FMI DESCRIPTION
CUMMINS DESCRIPTION
190
0
2468
Engine Speed
Data Valid but Above Normal
Operational Range - Most
Severe Level
Engine Crankshaft Speed/Position - Data Valid
But Above Normal Operating Range -
Moderately Severe Level
190
2
689
Engine Speed
Data Erratic, Intermittent or
Incorrect
Primary Engine Speed Sensor Error – Data
Erratic, Intermittent, or Incorrect
190
2
2321
Engine Speed
Data Erratic, Intermittent or
Incorrect
Engine Speed / Position Sensor #1 - Data
Erratic, Intermittent, or Incorrect
191
9
3328
Transmission Output Shaft
Speed
Abnormal Update Rate
Transmission Output Shaft Speed - Abnormal
update rate
191
16
349
Transmission Output Shaft
Speed
Data Valid but Above Normal
Operating Range - Moderately
Severe Level
Transmission Output Shaft Speed - Data Valid
but Above Normal Operational Range -
Moderately Severe Level
191
18
489
Transmission Output Shaft
Speed
Data Valid but Below Normal
Operating Range - Moderately
Severe Level
Transmission Output Shaft Speed - Data Valid
but Below Normal Operational Range -
Moderately Severe Level
411
2
1866
Engine Exhaust Gas
Recirculation 1 Differential
Pressure
Data Erratic, Intermittent or
Incorrect
Exhaust Gas Recirculation (EGR) Valve Delta
Pressure - Data Erratic, Intermittent or
Incorrect
411
3
2273
Engine Exhaust Gas
Recirculation 1 Differential
Pressure
Voltage Above Normal, or
Shorted to High Source
Exhaust Gas Recirculation (EGR) Valve Delta
Pressure Sensor Circuit - Voltage Above
Normal, or Shorted to High Source
411
4
2274
Engine Exhaust Gas
Recirculation 1 Differential
Pressure
Voltage Below Normal, or
Shorted to Low Source
Exhaust Gas Recirculation (EGR) Valve Delta
Pressure Sensor Circuit - Voltage Below
Normal, or Shorted to Low Source
412
3
2375
Engine Exhaust Gas
Recirculation 1 Temperature
Voltage Above Normal, or
Shorted to High Source
Exhaust Gas Recirculation (EGR)
Temperature Sensor Circuit - Voltage Above
Normal, or Shorted to High Source
412
4
2376
Engine Exhaust Gas
Recirculation 1 Temperature
Voltage Below Normal, or
Shorted to Low Source
Exhaust Gas Recirculation (EGR)
Temperature Sensor Circuit - Voltage Below
Normal, or Shorted to Low Source
412
15
2961
Engine Exhaust Gas
Recirculation 1 Temperature
Data Valid but Above Normal
Operating Range - Least
Severe Level
Exhaust Gas Recirculation (EGR)
Temperature - Data Valid but Above Normal
Operating Range - Least Severe Level
412
16
2962
Engine Exhaust Gas
Recirculation 1 Temperature
Data Valid but Above Normal
Operating Range - Moderately
Severe Level
Exhaust Gas Recirculation (EGR)
Temperature - Data Valid but Above Normal
Operating Range - Moderately Severe Level
441
3
293
Auxiliary Temperature 1
Voltage Above Normal, or
Shorted to High Source
Auxiliary Temperature Sensor Input # 1 Circuit
- Voltage Above Normal, or Shorted to High
Source
441
4
294
Auxiliary Temperature 1
Voltage Below Normal, or
Shorted to Low Source
Auxiliary Temperature Sensor Input # 1 Circuit
- Voltage Below Normal, or Shorted to Low
Source
441
14
292
Auxiliary Temperature 1
Special Instructions
Auxiliary Temperature Sensor Input 1 - Special
Instructions
441
14
1381
Auxiliary Temperature 1
Special Instructions
Auxiliary Temperature Sensor Input 1 - Special
Instructions
558
2
431
Accelerator Pedal 1 Low Idle
Switch
Data Erratic, Intermittent or
Incorrect
Accelerator Pedal or Lever Idle Validation
Circuit - Data Erratic, Intermittent, or Incorrect
558
13
432
Accelerator Pedal 1 Low Idle
Switch
Out of Calibration
Accelerator Pedal or Lever Idle Validation
Circuit - Out of Calibration
597
3
769
Brake Switch
Voltage Above Normal, or
Shorted to High Source
Brake Switch Circuit - Voltage Above Normal,
or Shorted to High Source
597
4
771
Brake Switch
Voltage Below Normal, or
Shorted to Low Source
Brake Switch Circuit - Voltage Below Normal,
or Shorted to Low Source
611
2
523
System Diagnostic Code #1
Data Erratic, Intermittent or
Incorrect
OEM Intermediate (PTO) Speed switch
Validation - Data Erratic, Intermittent, or
Incorrect
611
4
2186
System Diagnostic Code #1
Voltage Below Normal, or
Shorted to Low Source
Sensor Supply 4 Circuit - Voltage Below
Normal, or Shorted to Low Source
611
16
2292
System Diagnostic Code #1
Data Valid but Above Normal
Operating Range - Moderately
Severe Level
Fuel Inlet Meter Device - Data Valid but Above
Normal Operational Range - Moderately
Severe Level