10/12/2010
28
Company Confidential
1 High A/E temp
2 High Separator temp
3 Low Battery voltage
4 High Eng Temp
5 Low Engine Oil Press
INSTRUMENT PANEL (7/51) Tier 3
6 Comp Sensor
7 Low Engine Speed
8 Low Fuel
9 High Airfilter press
ALARMS & SHUTDOWNS Compressor
1
– High A/E Temp:
Indicates shutdown due to high
comp temp
2
– High Separator Temp:
Indicates shutdown due
to high temp at separator tank discharge
3
– Low Battery Voltage:
Alarm
– Indicates battery
or charging system malfunction
4
– High Engine Coolant Temp:
Indicates shutdown
due to high engine water temp
5
– Low Engine Oil Press:
Indicates shutdown due
to low engine oil press.
6
– Comp Sensor Failure:
Indicates press sensor
malfunction. Comp will not start.
7
– Low Engine Speed:
Indicates shutdown due to
low engine speed.
8
– Low Fuel Level:
Indicates shutdown due to low
fuel level. (Optional)
9
– Restricted Air Filter:
Alarm. Indicates
engine/comp air inlet filters need service ( Optional)
Company Confidential
1 High A/E temp
2 High Separator temp
3 Low Battery voltage
4 High Eng Temp
5 Low Engine Oil Press
INSTRUMENT PANEL (7/51) Tier 3
6 Comp Sensor
7 Low Engine Speed
8 Low Fuel
9 High Airfilter press
ALARMS & SHUTDOWNS Compressor
A
– Engine Comm Error:
Engine model not
recognized. Comp will start and operate within a
1700
– 2300 rpm range.
C
– CAN Comm Error:
CAN communication failure
E
– Generator Switch Enable Error:
Generator
enable switch on control panel is “ON” before
starting. Engine will not crank.
Company Confidential
1 High A/E temp
2 High Separator temp
3 Low Battery voltage
4 High Eng Temp
5 Low Engine Oil Press
INSTRUMENT PANEL (7/51) Tier 3
6 Comp Sensor
7 Low Engine Speed
8 Low Fuel
9 High Airfilter press
ALARMS & SHUTDOWNS Engine (
A
)
Failure flashes can be read on the Engine Failure
Lamp when the ON/OFF power switch is “ON” or
when the unit is running.
The Failure lamp is on for 2 seconds when the ECU
is powered up.
A lamp flash duration of 0.5 seconds is a “short” flash
A lamp flash duration of 1.5 seconds is a “long” flash
A flash sequence of “1 long and 3 short” would be
displayed by one flash with a 1.5 second duration
and 3 flashes with a 0.5 second duration.
When tow or more failures have occurred
simultaneously, the failure lamp will pause for 3
seconds between flash sequences.
Failure flash sequences continuously repeat with 3
second pauses until the failure is corrected.