22
OPERATING INSTRUCTIONS
7/20, P65
STARTING THE MACHINE
Open and close service valve to ensure no compressed air is present
in the system.
All normal starting functions are incorporated in the key operated
switch.
•
Turn the key switch to position 2 and hold for max 15 seconds to
allow the air inlet heater to reach working temperature.
•
Turn the key switch to position 3 (engine start position).
•
Release to position 1 when the engine starts.
In cold conditions or if there is difficulty starting first time:
•
Open the service valve fully, with no hose connected.
•
Complete the starting sequence as shown above.
•
Close service valve as soon as engine runs freely.
•
Do not allow machine to run for long periods with service valve
open.
•
Allow the engine to reach operating temperature.
•
At this point in the operation of the machine it is safe to apply full
load to the engine.
STOPPING THE MACHINE
•
Close the service valve.
•
Allow the machine to run unloaded for a short period of time to
reduce the engine temperature.
•
Turn the start switch to the
0
(off) position.
If the automatic blowdown valve fails to operate, then pressure must be
relieved from the system by means of the service valve(s).
EMERGENCY STOPPING
In the event that the unit has to be stopped in an emergency,
TURN
THE KEY SWITCH LOCATED ON THE INSTRUMENT PANEL TO
THE
0
(OFF) POSITION.
RE-STARTING AFTER AN EMERGENCY
If the machine has been switched off because of a machine
malfunction, then identify and correct the fault before attempting to re-
start.
If the machine has been switched off for reasons of safety, then ensure
that the machine can be operated safely before re-starting.
Refer to the
PRIOR TO STARTING
and
STARTING THE UNIT
instructions earlier in this section before re-starting the machine.
MONITORING DURING OPERATION
Should any of the safety shut–down conditions occur, the unit will stop.
These are:
•
Low engine oil pressure
•
High air discharge temperature
•
High engine coolant temperature
WARNING: Under no circumstances should volatile liquids such
as Ether be used for starting this machine.
NOTE:
Wear hearing protection at all times when the engine is
started with the service valve open and air is flowing from the valve.
NOTE:
As soon as the engine stops, the automatic blowdown valve
will relieve all pressure from the system.
CAUTION:
Never allow the machine to stand idle with pressure in the
system.
CAUTION:
To ensure an adequate flow of oil to the compressor at
low temperature, never allow the discharge pressure to fall below 3,5
bar (51psi).
Summary of Contents for 7/20
Page 9: ...DECALS 7 7 20 P65 Engine oil drain Cold Start Procedure...
Page 18: ...16 GENERAL INFORMATION 7 20 P65 VARIABLE HEIGHT RUNNING GEAR FIXED HEIGHT RUNNING GEAR...
Page 50: ......
Page 51: ......
Page 52: ......