36
MAINTENANCE
7/20, P65
COMPRESSOR LUBRICATION
Portable Compressor Fluid Chart
Refer to these charts for correct compressor fluid required. Note that
the selection of fluid is dependent on the design operating pressure of
the machine and the ambient temperature expected to be encountered
before the next oil change.
Note: Fluids listed as preferred" are required for extended
warranty.
Compressor oil carryover (oil consumption) may be greater with
the use of alternative fluids.
Preferred Doosan Fluids - Use of these fluids with original Doosan
branded filters can extend airend warranty. Refer to operator's manual
warranty section for details or contact your Portable Power
representative.
Design Operating
Pressure
Ambient
Temperature
Specification
100 psi to 300 psi
-10
°
F to 125
°
F
(-23
°
C to 52
°
C)
Preferred:
PRO-TEC
Alternate:
ISO Viscosity Grade
46 with rust and
oxidation inhibitors,
designed for air
compressor service
350 psi
-10
°
F to 125
°
F
(-23
°
C to 52
°
C)
Preferred:
XHP 605
Alternate:
XHP 405
ISO Viscosity Grade
68 Group 3 or 5 with
rust and oxidation
inhibitors designed
for air compressor
service.
24,1bar
(350 psi)
65
°
F to 125
°
F
(18
°
C to 52
°
C)
Preferred:
XHP 605
XHP1001
RATED OPERATING PRESSURE
consult factory
consult
factory
Doosan Preferred Fluids
1 gal.
(3.8 Litre)
5 gal.
(19.0 Litre)
55 gal.
(208.2Litre)
220 gal.
(836 litre)
PRO-TEC
-
89292973
89292981
22082598
XHP 605
-
22252076
22252050
22252068
XHP 1001
-
35612738
35300516
-
XHP 405
-
22252126
22252100
22252118
Summary of Contents for 7/20