44
OPTIONS
7/53
STARTING THE MACHINE
All normal starting functions are incorporated in the key operated
switch.
•
Turn the key switch to position
1
, the alternator charge light will
illuminate.
•
Turn the key switch to position
3
(engine start position).
•
Release to position
2
when the engine starts.
•
Release to position
1
when the alternator charge light is
extinguished.
At temperatures below 0°C or if there is difficulty starting first time:
Push and release button ‘A’.
•
Allow the engine to reach operating temperature.
•
At this point in the operation of the machine it is safe to apply full
load to the engine.
STOPPING THE MACHINE
•
Close the service valve.
•
Allow the machine to run unloaded for a short period of time to
reduce the engine temperature.
•
Turn the start switch to the
0
(off) position.
If the automatic blowdown valve fails to operate, then pressure must be
relieved from the system by means of the service valve(s).
EMERGENCY STOPPING
In the event that the unit has to be stopped in an emergency,
TURN
THE KEY SWITCH LOCATED ON THE INSTRUMENT PANEL TO
THE
0
(OFF) POSITION.
RE-STARTING AFTER AN EMERGENCY
If the machine has been switched off because of a machine
malfunction, then identify and correct the fault before attempting to re-
start.
If the machine has been switched off for reasons of safety, then ensure
that the machine can be operated safely before re-starting.
Refer to the
PRIOR TO STARTING
and
STARTING THE UNIT
instructions earlier in this section before re-starting the machine.
DECOMMISSIONING
When the machine is to be permanently decommissioned or
dismantled, it is important to ensure that all hazard risks are either
eliminated or notified to the recipient of the machine. In particular:-
•
Do not destroy batteries or components containing asbestos
without containing the materials safely.
•
Do not dispose of any pressure vessel that is not clearly marked
with its relevant data plate information or rendered unusable by
drilling, cutting etc.
•
Do not allow lubricants or coolants to be released into land surfaces
or drains.
•
Do not dispose of a complete machine without documentation
relating to instructions for its use.
MAINTENANCE
General
Ensure all electrical equipment is properly maintained and controlled.
Ensure all earth connections are secure and regularly maintained.
Earth leakage circuit breaker (ELCB)
The earth leakage circuit breaker must be mechanically tested daily by
pushing the test button with the machine in its
no load condition
. The
ELCB should trip to the
off
(down) position.
WARNING: Under no circumstances should volatile liquids such
as Ether be used for starting this machine.
CAUTION:
Do not start or stop the machine with the compressor/
generator mode switch in the Generator position.
NOTE:
Wear hearing protection at all times when the engine is start-
ed with the top open and air is flowing from the valve.
NOTE:
As soon as the engine stops, the automatic blowdown valve
will relieve all pressure from the system.
CAUTION:
Never allow the machine to stand idle with pressure in the
system.
Summary of Contents for 7/53
Page 2: ......
Page 4: ......
Page 11: ...DECALS 7 7 53 Engine oil drain...
Page 15: ...GENERAL INFORMATION 11 7 53 7 53 FIXED HEIGHT RUNNING GEAR 7 53 VARIABLE HEIGHT RUNNING GEAR...
Page 34: ...30 ELECTRICAL SYSTEM 7 53 7 53...
Page 36: ...32 ELECTRICAL SYSTEM 7 53 7 53...
Page 44: ...40 OPTIONS 7 53 WATER SEPARATOR MAINTENANCE FIGURE 4 FIGURE 5 FIGURE 1 FIGURE 2 FIGURE 3...
Page 58: ......
Page 59: ......
Page 60: ......