OPTIONS
47
7/53
A.C. Electrical Power Schematic Diagram. 230V 1 - phase.
Valid for units with component box located inside the machine, above the
generator.
KEY
CB1/
RCD
Circuit breaker 32A
CB2
Circuit breaker 16A
CB3
Circuit breaker 16A
F1
Fuse 1A
F2
Fuse 2A
G
Alternator - 1 phase
GND
Earth stud
KM1
Contactor
P1
Connector - voltmeter
P3
Connector - generator enable switch
SK1
Socket outlet 32A/230V
SK2
Socket outlet 16A/230V
SK3
Socket outlet 16A/230V