OPERATING INSTRUCTIONS
14
9/235
COMMISSIONING
Upon receipt of the unit, and prior to putting it into service, it is
important to adhere strictly to the instructions given below in
PRIOR TO
STARTING.
Ensure that the operator reads and
understands
the decals and
consults the manuals before maintenance or operation.
Ensure that the position of the
emergency stop
device is known and
recognised by its markings. Ensure that it is functioning correctly and
that the method of operation is known.
Ensure that all transport and packing materials are discarded.
Ensure that the correct fork lift truck slots or marked lifting / tie down
points are used whenever the machine is lifted or transported.
When selecting the working position of the machine ensure that
there is sufficient clearance for ventilation and exhaust requirements.
Adequate clearance needs to be allowed around and above the
machine to permit safe access for specified maintenance tasks.
Ensure that the machine is positioned securely and on a stable
foundation. Any risk of movement should be removed by suitable
means, especially to avoid strain on any rigid discharge piping.
COMPRESSOR MOUNTING
Portable compressors, which are modified to remove the running gear
and mount the machine direct to trailers, truck beds or frame, etc. may
experience failure of the enclosure, frame, and/or other components.
It is necessary to isolate the compressor package from the carrier base
with a flexible mounting system. Such a system must also prevent
detachment of the package from the carrier base in the event the
isolators fail. Contact Doosan representative for flexible mounting kits.
Warranty does not cover failures attributable to mounting of the
compressor package to the carrier base unless it is an Doosan
provided system.
Attach the battery cables to the battery(s) ensuring that they are
tightened securely
.
Attach the positive cable before attaching the
negative cable.
WARNING: All air pressure equipment installed in or connected
to the machine must have safe working pressure ratings of at least
the machine rated pressure, and materials compatible with the
compressor lubricant
(refer to the
GENERAL INFORMATION
section).
WARNING: If more than one compressor is connected to one
common downstream plant, effective check valves and isolation
valves must be fitted and controlled by work procedures, so that
one machine cannot accidently be pressurised / over pressurised
by another.
WARNING: When flexible discharge hoses are used, it is
recommended that safety retaining wires are fitted.