Doosan Robotics User Manual v2.6.1
106
7.5.15
Collision Sensitivity Reduction Zone Settings
To set the Collision Sensitivity Reduction Zone, tap the
Add button on the
Robot
Workcell and
select
Collision Sensitivity Reduction Zone> Cuboid
,
Cylinder
,
Multi-plane Box, Sphere or Tilted
Cuboid
. The safety password is required during setup and enablement.
1
Enter the Workcell Name in the Workcell Name field on the top of the Workcell Setting screen.
2
Set the pose information according to the Zone shape along with the
Valid Space
and
Zone
Margin
in the
Geometry tab
.
3
Set the
override option
,
TCP/Robot Limits and Dynamic Zone Enable
in the
Parameters tab
and press
Draft
.
Warning
Collision Sensitivity Reduction Zone
is a
High Priority Zone
.
High Priority Zones
have priority over the other Zones and global
Robot Limits
setting. And If
multiple
High Priority Zones
are overlapped, the safety function uses the
LEAST
restricted
safety limit. For these reasons, the size of
High Priority Zone
should be specified as small as
possible for safety
4
Verify that all parameters displayed are the same as what are Intended to be set, then check
Confirm draft
and press
Confirm
5
Press the Activate Toggle button to apply the
Collision Sensitivity Reduction Zone
.