Doosan Robotics User Manual v2.6.1
216
No.
Item
Description
1
Task Monitoring Tab
It is the tab that displays monitoring information necessary for
executing the input signal and Task of Smart Pendant.
2
Log Tab
It is the tab that displays the log messages collected during task
execution.
3
Smart Pendant Enable
Signal
When the Smart Pendant is connected to the controller, it is
displayed as Checked (green).
4
Homming Signal
When the homming button of the Smart Pendant is pressed, the
indicator is displayed as Checked (green).
5
Servo On/Off Signal
Displays the Servo On/Off status
6
Function Button
Signal
Indicators of P1-P4 press status
7
Current Task
Area displaying the task to be used by the Smart Pendant
8
Total Time
Total Task play time
9
Total Count
Count of Task loops
10
Average Cycle Time
Average play time of each task cycle
11
TCP Indicator
TCP information used by the current task
12
Tool Weight Indicator
Tool Weight information used by the current task
13
Tool Shape Indicator
Tool Shape information used by the current task
14
Collision
Collision threshold information
15
Force
Force information
16
Digital / Flange I/O
information
Digital / Flange I/O information
17
Close
Button to close the Smart Pendant mode.
Note
If the Emergency Stop or Protective Stop occurs in Smart Pendant Mode, it is handled as follows:
1.
Emergency Stop: An emergency stop popup is displayed. After removing the cause of
emergency stop - pulling or twist the emergency stop switch for reset, the popup closes
automatically.
2.
Protective Stop causing the transition to
Servo Off
state: A red protective stop popup is
displayed. If the Smart Pendant’s
Servo On
button is pushed after removing the cause of
protective stop, the robot servo drives turn on and the popup closes automatically.
3.
Protective Stop causing the transition to
Interrupted
state: A yellow protective stop popup is
displayed. If Smart Pendant’s
Reset
button is pushed after removing the cause of protective
stop, the robot state chages to normal standby state – Manual Standby, Auto Standby, or HGC
Summary of Contents for A0509