Loosen the lock nuts of the rocker arm adjusting screws and push the specified feeler
gauge and adjust the valve clearance with adjusting screw respectively.
6.1.3. Method of adjusting the valve clearance
1) Loosen the lock-nuts
aa
using a ring span-
ner.
2)
Insert a thickness gauge of 0.3mm
between valve stem
aa
and rocker arm
aa
.
3) Turn the adjusting bolts
aa
using a screw
driver until the gauge can be pulled out
with some restriction.
4) After the adjustment fix the adjusting bolt
not to rotate and tighten the lock-nut at
the same time.
5) Measure the clearance one more time
and if necessary adjust again.
- 47 -
Model
Intake Valve
Exhaust Valve
D1146/PU086
D1146T/PU086T
0.3 mm
0.3 mm
P086TI
1
3
2
4
EA0O4014
4
1
3
2