Precautions on connection from air sources to machine
(1) Make sure the air pipeline from the site ceiling is bent upwards before running it
down to the machine. See the figures below. Do not run the pipeline to a side or
straight down to the machine. The pipeline will contain water inside, affecting the
performance of the machine.
However, if this happens, ask the installer to install the pipeline again as
instructed above.
(2) The pipeline from the site ceiling is then connected to the machine through a
distribution tank that filters the water generated from compressed air.
▪
It is advisable to use an air dryer such as the distribution tank.
3) Use an air hose or tube with an inner diameter
of at least 9 mm.