OP001014
3-3
Operation
4.
Set pilot cutoff switch to "O" (LOCK) position. This will
"LOCK" pilot control valve lever (joystick).
5.
Set reverse fan switch to "O" (OFF) position. This will
prevent damage to the cooling system during normal
operation.
6.
Rotate starter key to "I" (ON) position. All indicator lights
should turn "ON."
NOTE:
If unit is equipped with and emergency steering
system. Test system before starting engine. If
system does not function properly, do not start
unit. Follow test procedure given with test
switch.
7.
Rotate starter key to "START" position. Starter motor
should crank immediately, and engine should start within a
few seconds.
Figure 4
HBOI111L
O
I
O
I
HAAH0040
Figure 5
FG000084
O
I
Figure 6
FG000085
O
I
Figure 7