OP000597
2-59
Operating Controls
MISCELLANEOUS ELECTRICAL
DEVICES
Cabin Light
A light is installed on the top of the operator's compartment.
The light will work despite starter switch position.
NOTE:
If light is left "ON" for a long time while the engine is
not running, the battery will be discharged.
Pilot Cutoff Switch
When the safety lever is put into the "LOCK" position, the switch
deactivates the work and travel levers. With the work and travel
levers deactivated, no digging/operational work can be done.
Circuit Breaker
A main circuit breaker is in the battery box. It will automatically
cut off in case of an electrical short circuit or overload. This will
prevent the electric wiring and components from being burned or
damaged.
If the circuit breaker is cut off, check all related circuits, this
means something is wrong in the electric circuit.
After maintenance, press the red button for normal operation of
circuit breaker.
Figure 124
FG000417
FG000211
Figure 125
HAAE2110
Figure 126
Summary of Contents for DX140LC