OP000599
4-45
Inspection, Maintenance and Adjustment
1,000 HOUR / 6 MONTH SERVICE
Perform All Daily, 50, 250 and 500 Hour
Service Checks
Grease Swing Reduction Device
1.
Position the machine on firm, level ground. Lower the front
attachment to the ground and shut down engine.
2.
Remove air vent plug (1, Figure 73) from swing reduction
device.
3.
Press grease fitting and inject grease with the grease gun
on the marked point (2, Figure 74).
4.
Install air vent plug (1, Figure 73) in swing reduction
device.
Figure 73
1
F
G006316
Figure 74
2
FG009576