OP000530
4-51
Inspection, Maintenance and Adjustment
3.
Remove filter (Figure 92) and replace with new one.
4.
Reassemble in reverse order.
Check Air Conditioner Refrigerant
1.
Run engine at about 1,800 rpm. Operate for a minimum of
ten minutes to stabilize the system.
2.
Press the "HI" fan speed switch to set maximum air flow.
3.
Put the temperature control switch in maximum cooling
position.
4.
Press the "Internal Air Circulation" switch.
5.
Compare the flow of bubbles in the sight glass of receiver
dryer with the drawings in the following table.
Figure 92
FG000342
FG006774
Figure 93
WARNING!
Mixing of tobacco smoke and freon is deadly.
Do not smoke while servicing or recharging
air-conditioning system.
CAUTION!
Overfilling refrigerant may cause dangerous
high-pressure and poor cooling action; and low
refrigerant level may cause compressor damage.
Always maintain refrigerant at normal level.
Summary of Contents for DX190W
Page 2: ......
Page 71: ...OP000528 2 3 Operating Controls ...
Page 128: ...OP000528 Operating Controls 2 60 CD Player Optional AST DIR FG000109 Figure 135 ...
Page 196: ......
Page 292: ...OP000530 Inspection Maintenance and Adjustment 4 96 ...
Page 304: ...OP000440 6 8 Troubleshooting ...