OP000528
Operating Controls
2-50
Adjusting Flow Rate
Use "UP" (
) or "DOWN" (
) buttons to adjust flow rate.
"UP" (
) button is used to increase a flow rate.
"DOWN" (
) button is used to decrease a flow rate.
Pump flow setting is at rated engine speed, for only the output of
one pump.
Pump displacement will vary according to changes in engine
rpm.
Escape
A.
Press flow control button (
normal display screen and save the flow rate setting.
B.
If there is no adjustment for twenty seconds, the flow
control screen will return to the normal display screen.
FLOW CONTROL
ESC: CANCEL
FG000254
: APPLY
Figure 109
Breaker
Flow Control Step
Pump Flow Setting (l/min)
1
38
2
61
3
80
4
91
5
101
6
133
7
142
8
149
9
165
10
168
FLOW CONTROL
ESC: CANCEL
FG000255
: APPLY
Figure 110
Shear
FLOW CONTROL
ESC: CANCEL
FG000254
: APPLY
Figure 111