OP000530
4-43
Inspection, Maintenance and Adjustment
Change of Fuel Prefilter
1.
Open the left side door to access fuel prefilter.
2.
Position a small container under prefilter. Drain fuel by
opening drain valve on bottom of filter.
NOTE:
Dispose of drained fluids according to local
regulations.
3.
Remove the bowl using supplied tool.
4.
Remove the cartridge.
5.
Coat surface of packing (2, Figure 76) with fuel on new
cartridge (1).
6.
Tighten the cartridge by hand until the packing comes into
contact with the surface of the filter housing head.
7.
When it reach the surface, tighten the cartridge about 3/4
of a turn more.
8.
Coat surface of seal (3, Figure 76) with fuel, and tighten
the bowl with tool.
Figure 74
FG006640
FG008157
Figure 75
2
1
FG000428
3
Figure 76