2-39
DX380LC-7
21. Ultrasonic sensor failure
Appears in the event of a failure in the ultrasonic sensor.
22. Engine rpm and starting restricted by TMS or TMS terminal failure
Appears when there is a problem in the TMS terminal.
23. Coolant level warning
Appears when there is a problem with the coolant level.
Add coolant if there is not enough coolant.
24. Seat belt
Appears when the seat belt is not worn.
25. No smart key
Appears when no smart key is detected.
26. Failed to detect smart key
Appears when the machine fails to recognize the smart key.
27. Low smart key battery
Appears when the smart key is low on battery power.
28. Return filter clogged
Indicates that the return filter is clogged.
When this symbol appears on the screen, be sure to stop the machine immediately and replace the return
filter. After replacing the return filter, start the engine again and check whether the warning symbol is gone.
29. Regeneration prohibition
It is illuminated when regeneration is prohibited.
Refer to "After Treatment System" on page 3-20, for more information.
30. Active regeneration operating
The lamp turns on when automatic regeneration begins.
Refer to "After Treatment System" on page 3-20, for more information.
31. Manual regeneration
The lamp turns on when forced regeneration begins.
Refer to "After Treatment System" on page 3-20, for more information.
32. GPS antenna failure
Appears when the GPS antenna is malfunctioning or disconnected and cannot be recognized.