DX380LC-7
Operation
3-22
Active Regeneration
No action by the operator is required to start active regeneration.
Regeneration is automatically activated by the engine control
unit (ECU). Contact your DOOSAN distributor for more
information.
Active regeneration can occur anytime the engine is running,
while operating the machine or when the machine is parked.
During regeneration, the regeneration light and the high
temperature warning light turn "ON" to alert the operator of hot
engine exhaust gases. Machine operation can continue, but the
operator should keep engine exhaust away from flammable
materials. The operator can choose to "inhibit" active
regeneration, if operating conditions are not favorable to hot
engine exhaust temperatures (e.g. working near flammable
materials).
When completed, the regeneration lights on the monitor will turn
"OFF".
NOTICE
Continue operating the machine normally and avoid
excessive idling during active regeneration.
Do not shut down engine during manual regeneration.