3-77
DX380LC-7
Three-digit LED Display
The display is off in normal mode. It can be activated by briefly
pressing one of the two push buttons (
)(
). Current values
and preset parameters are displayed. The display also serves to
guide and prompt the operator while programming operating
parameters.
WL1300072
Figure 132
Display
Meaning
Statement
Control function
t = TIMER
PA = PAUSE
The control unit is functioning
as a timer and is currently in
PAUSE mode.
Part of lubrication cycle; entry
and display value in hours.
t = TIMER
CO = CONTACT
The control unit is functioning
as a timer and is currently in a
pump cycle (CONTACT).
CONTACT = time during which
the pump delivers lubricant;
entry and display value in
minutes.
c = Cycle
O = OFF
P = Pressure
Display the "Monitoring settings"
menu.
Monitoring OFF
The CS and PS monitoring
functions are switched off.
No system monitoring
Cycle Switch
Piston detector
(progressive
systems)
Piston detector monitoring is
active.
The piston detector is
monitored for signals during
the CONTACT pump cycle.
Low Level
Fault: fill level too
low.
The minimum fill level has
been reached in the reservoir.
Fault Cycle Switch
Fault: Piston detector
No signal from piston detector
during pump cycle.
The control unit is currently in
FAULT mode.
The operational sequence
has been stopped.
Operation Hour Meter
The values shown after this are
the number of hours, the
control unit has operated.
The control unit is currently in
FAULT mode.
The operational sequence
has been stopped.