DX380LC-7
Inspection, Maintenance and Adjustment
4-72
11. Fit a new paper insert on the inside of the rotor cover.
12. Fit the strainer onto the rotor.
13. Fit a new O-ring by sliding it over the strainer.
14. Refit the rotor cover. Ensure that the O-ring is not outside
the cover.
15. Screw the rotor nut back on by hand.
16. Check that the shaft is not damaged or loose.
If the shaft is damaged, it should be renewed.
Secure the shaft with thread-locking fluid if it is loose. First
clean thoroughly using a suitable solvent. Tighten the rotor
shaft using socket wrench.
•
Torque: 45 N.m (4.6 kg.m, 33.2 ft lb)
NOTE:
Take care not to damage the rotor shaft.
17. Refit the rotor and screw it by hand to make sure it rotates
easily.
DS1605872
1
4
3
2
DS1605873
Figure 101
DS1605874
Figure 102
FG019032