2-27
DX380LC-7
Functional Check
If the start mode switches to ACC mode, switch/button indicators on
the display monitor turn on, the warning indicator turns on and the
warning buzzer sounds for two seconds.
The Doosan logo is displayed on the screen during functional
checks.
Setting a Password
In the event that a password setting function is installed, a
screen for entering the password appears after the functional
check is complete.
By default, the password setting function is not provided when
the machine is released from the factory.
For more information about setting passwords, please refer to
"Operator Management" on page 2-62.
1. Fuel Gauge
The fuel gauge indicates the amount of fuel remaining in
the fuel tank.
White range - Normal amount of fuel.
Red range - Not enough fuel.
If the needle moves into the red range, the fuel level
symbol is displayed. In such cases, be sure to stop the
engine and add fuel immediately.
NOTE:
For information about the location of this
warning indicator and other indicators, please
refer to "22. Display Warning Symbols" on
page 2-35.
Check the fuel level on firm, level ground.
Figure 46
DS1900405
DS1900406
Figure 47
NOTICE
The machine cannot be operated normally if the password
is incorrect.
DS1900407
Figure 48