Inspection, Maintenance and Adjustment
4-16
5.
If oil level is above the "H" mark drain oil.
A.
Shut down engine and wait for the hydraulic oil to
cool down.
B.
Drain the excess oil from drain plug (Figure 19) at the
bottom of the tank into a suitable container, using a
hose at the point (plug).
NOTE:
Dispose of drained fluids according to local
regulations.
Check for Leaks in Hydraulic System
1.
Perform a daily walk-around inspection to make sure that
the hoses, piping, fittings, cylinders and hydraulic motors
are not showing any signs of leakage. If any is noted,
determine the source of the leak and repair.
Figure 19
FG015797