4-47
Inspection, Maintenance and Adjustment
Change Air-Conditioning Outer Filter
The unit is equipped with an air filtration system which filters out
dirt and dust particles from air being circulated into operator's
cabin. This filter should be cleaned out.
NOTE:
In the event that the unit is being operated in a dusty
environment, the cleaning and replacement should
be performed more frequently. If filter is damaged,
replace damaged filter with a new one.
NOTE:
All right and left call outs are based on the operator
being seated in the operator's seat facing the front.
1.
Open the door in the left front of the machine, then remove
four wing bolts and washers, and access cover (1, Figure 80).
2.
Open the cover by unscrewing the knob (1, Figure 81) in
the rear of the cabin.
3.
Remove filter (Figure 82) and replace with new one.
4.
Reassemble in reverse order.
FG016162
Cover
Figure 80
WARNING
All service and inspection of air-conditioning system
should be performed with the starter switch in the "O"
(OFF) position.
Figure 81
FG000441
1
Figure 82
FG000342