Inspection, Maintenance and Adjustment
4-52
Replace Outer and Inner Air Cleaner
Elements
NOTE:
Replace outer element after cleaning 5 times or every
2,000 hours of service.
NOTE:
Replace inner element whenever a new outer
element is installed.
If there is clogged filter signal on the gauge panel, use the
following procedure.
1.
Open the access door at the rear of the cabin.
2.
Remove the evacuator valve (1, Figure 93) and air cleaner
cover (2).
NOTE:
Inspect evacuator valve seal lips for wear or
damage. Replace valve if necessary. Install
evacuator valve with lips parallel to the cover.
3.
Remove outer filter (3, Figure 93) from the air cleaner
housing.
4.
Clean the air cleaner cover and the inside of the air cleaner
housing.
5.
Remove inner filter (4, Figure 94).
6.
Clean out inside of air cleaner housing. Do not use
compressed air to blow out housing.
7.
Install new inner filter. Do not clean and reuse inner
element.
8.
Install new outer filter.
9.
Install air cleaner cover and evacuator valve.
NOTE:
Make sure that all gaskets and cover are
properly installed and seated.
WARNING
Never clean or attempt to remove the air cleaner element if
the engine is running.
Figure 93
FG016134
1
2
FG016115
1
2
4
3
Figure 94
Summary of Contents for DX700LC
Page 2: ......
Page 72: ...OP001120 Safety 1 66 ...
Page 142: ...OP001121 Operating Controls 2 70 ...
Page 188: ...OP001122 Operation 3 46 ...
Page 197: ...OP001123 4 9 Inspection Maintenance and Adjustment ...
Page 282: ...OP001123 Inspection Maintenance and Adjustment 4 94 ...
Page 298: ...OP000030 Troubleshooting 6 6 ...
Page 301: ...OP001125 7 3 Specification ...
Page 308: ...OP001125 Specification 7 10 ...
Page 314: ...950106 00012E Index 8 6 ...