4-19
Inspection, Maintenance and Adjustment
Check Oil Level of Swing Reduction
Device
NOTE:
When checking level using a dipstick always
remove and wipe it clean before making final
level check.
1.
Remove dipstick (1, Figure 25) and wipe the oil from the
dipstick with a cloth.
2.
Insert dipstick (1, Figure 25) fully into dipstick tube.
3.
When dipstick is pulled out, oil level must be between
"HIGH" and "LOW" marks on dipstick.
NOTE:
If oil is above "HIGH" mark on dipstick, some
must be drained to proper level.
4.
If the oil does not reach the "L" mark on the dipstick, add oil
through fill port (2, Figure 25).
5.
If the oil level exceeds the "H" mark on the dipstick, release
the drain plug (Figure 27). Drain the excessive oil into a
suitable container.
NOTE:
Dispose of drained fluids according to local
regulations.
Figure 25
FG
0
15801
2
2
1
1
WARNING
The gear oil is very hot after the machine has been
operating. Shut all systems down and allow them to cool.
Before fully removing any motor case inspection port plug,
etc., loosen the plug slightly to allow pressurized air to
escape.
L
H
FG000419
Figure 26
Figure 27
FG015802
Summary of Contents for DX700LC
Page 2: ......
Page 72: ...OP001120 Safety 1 66 ...
Page 142: ...OP001121 Operating Controls 2 70 ...
Page 188: ...OP001122 Operation 3 46 ...
Page 197: ...OP001123 4 9 Inspection Maintenance and Adjustment ...
Page 282: ...OP001123 Inspection Maintenance and Adjustment 4 94 ...
Page 298: ...OP000030 Troubleshooting 6 6 ...
Page 301: ...OP001125 7 3 Specification ...
Page 308: ...OP001125 Specification 7 10 ...
Page 314: ...950106 00012E Index 8 6 ...