G80XW/XF, G115XW/XF, G150XW/XF, G200XW/XF - 50HZ
OPERATION & MAINTENANCE MANUAL
121
G100XW/XF, G135 XW/XF, G170XW/XF, G225XW/XF - 60Hz
TABLE OF CHARACTERISTICS
TAL 44, TAL 46
Table of average values: Alternator - 4 pole - 50 Hz - Winding No. M/ M1 (4-wire) - no. 6S (6-wire) - no. 6 (12-wire) The
voltage and current values are given for no-load operation and operation at rated load with separate field excitation. All
values are given at ± 10% (for exact values, consult the test report) and are subject to change without prior warning.
Three-phase: 4-pole, SHUNT excitation 6 and 12 wire Resistances at 20 °C (Ω)
Field excitation current i exc (A)
400V - 50 Hz
“i exc”: excitation current of the exciter field
For 60 Hz machines, the "i exc" values are
approximately 5 to 10% lower.
Table of weights (values given for information only)
Type
Stator L/N
Rotor
Exciter
Field
Exciter
Armature
(G80)
TAL44-C
0.050
2.35
11.65
0.790
(G100, G115)
TAL44-E
0.034
2.89
12.94
0.920
(G135, G150)
TAL44-J
0.029
3.15
12.94
0.920
(G170)
TAL46-A
0.023
0.51
10.01
0.1001
(G200)
TAL46-B
0.023
0.51
10.01
0.1001
(G225)
TAL46-C
0.020
0.54
10.01
0.1001
Type
No Load
At Rated Load
(G80)
TAL44-C
0.8
2.75
(G100, G115)
TAL44-E
0.67
2.57
(G135, G150)
TAL44-J
0.66
2.79
(G170)
TAL46-A
0.95
3.40
(G200)
TAL46-B
0.95
3.72
(G225)
TAL46-C
1.01
3.84
Type
Total weight (kg)
Rotor (kg)
(G80)
TAL44-C
295
127
(G100, G115)
TAL44-E
368
160
(G135, G150)
TAL44-J
398
172
(G170)
TAL46-A
569
243
(G200)
TAL46-B
599
243
(G225)
TAL46-C
674
255