G80XW/XF, G115XW/XF, G150XW/XF, G200XW/XF - 50HZ
OPERATION & MAINTENANCE MANUAL
72
G100XW/XF, G135 XW/XF, G170XW/XF, G225XW/XF - 60Hz
REGULAR INSPECTION TABLE
GENERAL CONDITIONS
Regular inspection and replacement according to the recommended regular inspection table allows you to maintain the
engine with optimum conditions and best performance for a long period and prevent unexpected accidents in advance.
( o : Inspection and Adjustment • : Replacement)
a. First 50hr
b. Clean
Check Points
Daily
Inspection interval (Hours)
Remarks
First
50
200
400
600
1,200
Cooling
system
Check for leakage (hoses, clamp)
o
Check the coolant water level
o
Change the coolant water
•
Adjust the V-belt tension
o
Every
2,000hrs
Clean the radiator
o
Lubrication
system
Check for leakage
o
Check the oil level gauge
o
Change the lubricating oil
•
a
•
Replace the oil filter cartridge
•
a
•
Fuel system
Check the fuel line for leakage
o
Clean the fuel strainer of fuel feed
pump
o
Remove sediment from fuel tank
o
Drain the water in separator
o
Replace the fuel filter element
•
Check fuel Injection timing
o
When
necessary
Check the injection nozzles
o
When
necessary
Intake /
Exhaust
system
Check the intercooler for leakage
(hoses, clamp)
o
Clean and change the air cleaner
element
o
b
•
Clean the inter-cooler air fins
o
Clean the turbocharger
Every
2,000hrs
Engine adjust
Check the state of exhaust gas
o
Check the battery charge
o
Check the compression pressure
o
When
necessary
Adjust Intake/Exhaust valve
clearance
o
a
When
necessary