MAINTENANCE
41
7/20, P65
COMPRESSOR LUBRICATION
Portable Compressor Fluid Chart
Refer to these charts for correct compressor fluid required. Note
that the selection of fluid is dependent on the design operating
pressure of the machine and the ambient temperature expected to
be encountered before the next oil change.
Design Operating
Pressure
Ambient
Temperature
Specification
6.9bar
−
20.7bar
(100 psi
−
300 psi)
−
10
F to 125
F
(
−
23
C to 52
C)
IR Pro
−
Tec
Mil –PRF 2104G
SAE 10W
6.9bar
−
20.7bar
(100 psi
−
300 psi)
−
40
F to 125
F
(
−
40
C to 52
C)
IR Performance 500
Mil
−
L
−
46167
24.1bar
(350 psi)
−
10
F to 125
F
(
−
23
C to 52
C)
65
F to 125
F (18
C
to 52
C)
−
40
F to 65
F
(
−
40
C to 18
C)
IR XHP 505
IR XHP1001
IR Performance 500
Mil
−
L
−
46167
34.5bar
(500 psi)
50
F to 125
F (10
C
to 52
C)
10
F to 65
F (
−
12
C
to 18
C)
below 10
F (
−
12
C)
IR XHP1001
IR XHP 505
Consult Factory
IR
XHP505
IR
XHP1001
IR
PER FORMANCE
500
IR
PRO
−
TEC
100
−
300 PSI
RATED OPERATING PRESSURE
350 PSI
500 PSI
IR
XHP 1001
IR
500
PERFORMANCE
IR
XHP505
10
F
125
F
50
C
40
C
30
C
20
C
10
C
0
C
−
10
C
−
20
C
−
30
C
−
40
C
104
F
86
F
65
F
50
F
32
F
14
F
−
10
F
−
22
F
−
40
F
consult
factory
Recommended Ingersoll Rand Fluids
−
Use of these fluids with
original IR filters can extend airend warranty. Refer to operator’s
manual warranty section for details or contact your IR
representative.
Recommended Fluid
3.8 Litre
19.0 Litre
208.2 Litre
IR Pro
−
Tec
36899698
36899706
36899714
IR XHP 505
35365188
35365170
IR Performance 500
35382928
35382936
35382944
IR XHP1001
35612738
35300516