-5-
-4-
*After entering the limits fine tuning mode, the original
preferred position
will not be deleted; If there is no button
operation within 2 minutes, it will arrive within 2 minutes, and the motor will turn to prompt, and automatically exit the
route adjustment mode; When fine-tuning the limit, press and P1 for more than 2S to exit the mode.
-3-
*Press STOP for 2S,the motor moves to preferred position automatically.
2 Remove preferred position
Press P2 (1 jog
and 1 beep
), press STOP (1 jog
and 1 beep
), STOP again(1 jog
and make a long
noise
), the preferred position is deleted.
3 Upper and Lower Limits Setting
2 Set lower limit
→
DOWN
DOWN
STOP
+
1 Set upper limit
→
+
UP
UP
STOP
*If exit the limits setting status before you finish the limit setting, then the motor will take the previous limits if has; After
the limits have been set successfully, the motor will enter the user mode.
Press UP for 2S, operate the motor to desired upper
position, press and hold UP and STOP buttons
simultaneously for 2S (2 jogs and 3 beeps), upper limit
is set.
Press DOWN for 2S, operate the motor to desired
lower position, press and hold DOWN and STOP
buttons simultaneously for 2S (2 jogs and 3 beeps),
lower limit is set.
1 Add A Preferred Position
User mode
1 Set preferred position
P2
→
→
P2
STOP
STOP
P2
→
→
P2
STOP
STOP
Check both upper and lower limits are set. Operate the
product to desired preferred position. Press P2 (1 jog
and 1 beep), press STOP(1 jog and 1 beep), STOP
again (2 jogs and 3 beeps), the preferred position is set.
*when in jog mode, press UP or DOWN once, the motor will be jog running, if press more than 2 second, the motor will
be continously running.
2
Jog Mode & Running Mode Switch
→
DOWN
STOP
UP
+
Press and hold UP and DOWN buttons simultaneously for 5S (1 jog),
press STOP (
1 jog
and make a long noise), switch to jog mode, If
motor jog twice and beep 3 times, switch to running mode.
3 Adjust Limits
1 Adjusting the upper limit
→
→
DOWN
UP
or
→
+
UP
STOP
+
UP
STOP
The new upper
limit position
Press and hold UP and STOP buttons for 5S (
1 jog
and make a long noise), operate the product to desired
new upper limit position, press and hold UP and STOP buttons for 2S(2 jogs and 3 beeps), the new upper
limit is programmed successfully.
2 Adjusting the lower limit
Press and hold DOWN and STOP buttons for 5S (
1 jog
and make a long noise), operate the product to
desired new lower limit position, press and hold DOWN and STOP buttons for 2S (2 jogs and 3 beeps), the
new lower limit is programmed successfully.
→
→
DOWN
UP
or
→
+
DOWN
STOP
+
DOWN
STOP
The new lower
limit position
•
Repeat same procedure will unpair additional emitter.
P2
P2
→
→
P2
P2(a)
P2(a)
P2(b)
4 Pair / Unpair Additional Emitter
Press P2 (1 jog and 1 beep) and P2 (1 jog and 1 beep) on existing
emitter, press P2 on new emitter to add (2 jogs and 3 beeps), new
emitter is paired to the motor.
Method one
Press P2 (1 jog and 1 beep) and P2 (1 jog and 1 beep and 1 beep) on
existing emitter, press STOP on new emitter for 2S to add (2 jogs and
3 beeps), new emitter is paired to the motor.
Method two
P2
P2
→
→
P2(a)
P2(a)
STOP(b)
P1
→
P1
•
Repeat same procedure will unpair additional emitter.
*(a) as existing emitter,(b) as new emitter to pair/unpair; Adding the emitter should be carried out when there is a limits;
All the setting of the motor will be kept after addiing the new emitter.
Press P1 button for 2S (1 jog), release button and make a long noise,
press STOP on new emitter for 2S to add (2 jogs and 3 beeps), new
emitter is paired to the motor.
Press P2 (1 jog and 1 beep), UP (1 jog and 1 beep), UP again (
2 jogs
and 1 beep
), the motor running speed is accelerated .
Method three
STOP(b)
→
→
P2
P2
UP
5 Speed Regulation
UP
1 Acceleration setting
*If the motor no response, it has already been the Max. or Min speed.
→
→
Press P2 (1 jog and 1 beep), DOWN (1 jog and 1 beep), DOWN again
(2 jogs and
1 beep
), the motor running speed is decelerated.
P2
P2
DOWN
DOWN
2 Deceleration setting
Quick Index
Settings
Steps
Pairing
Switch Rotating Direction
Upper and Lower Limits Setting
Adjust Limits
P1 (hold down 2s)
→
Stop (hold down 2s)
Up + Down (hold down 2s)
Set upper limit
Up (hold down 2s) → Up + Stop (hold down 2s)
Adjusting the upper limit
Up + Stop (hold down 5s) → Up or Down → Up + Stop (hold down 2s)
Adjusting the lower limit
Down + Stop (hold down 5s) → Up or Down → Down + Stop (hold down 2s)
Acceleration setting
P2 →
Up
→
Up
Deceleration setting
P2 →
Down
→
Down
Set lower limit
Down (hold down 2s) → Down + Stop (hold down 2s)
P2 →
Stop
→
Stop
5
Add / Remove Preferred Position
4
3
2
1
Jog Mode & Running
Mode Switch
Pair / Unpair Additional Emitter
Up + Down (hold down 5s) → Stop
P2(a) → P2 (a) → P2(b)
P2(a) → P2 (a) → Stop (b) (hold down 2s)
P1 (hold down 2s)
→
Stop (b) (hold down 2s)
6
7
8
Speed Regulation
Troubleshooting
Issues
Possible causes
Solution
The motor has no response
emitter battery is low capacity
Replace battery
Out of radio control range
Try control within closer range
The emitter cann't control
single motor
Multiple motors are paired to the
same channel.
Pair single motor with emitter correctly
Try to use multi-channel emitters to control multi-motor
projects, ensure each channel to control one single motor
The motor doesn't run or starts
too slowly or make loud noise
The motor stops during the
up and down running
Connections are incorrect.
Check connections
Installation is improper or overload
The motor has reached the lower limit
The running time more than 6min
Adjust the new lower limit
Consult the sales for more information
Check installation or overload
Radio interference / shielding
Check antenna on motor is intact and exposed. Check for
possible source of radio interference.
Power Failure Or Incorrect Connection
Double check power and cable connections, follow wiring
instructions.
Battery in motor is depleted
Recharge with compatible AC adaptor
Important Safety Instructions To Be Read Prior To Operation.
Please read following points of attention carefully before setting.
Setting Notice
1. Don’t operate motors when low voltage alarm.
2. Operating
:
①
The valid interval of the emitter button is 10S, the emitter will quit the set after 10S.
②
The motor will run or beep for hint, please do the next step after the hint.
3. Set the limit position
:
①
After the upper / lower limit setting, and the upper / lower limit positin can’t at the same position.
②
After the limit setting, with power off and memory function.
③
Limit delete will clear all limit memory.
④
It will exit limit setting when
prog
ram there is no operation for 2 minutes.
4. If the emitter lost, please set up again with the new emitter.
5.
One motor can store maximum 10 channels; after fully stored, if pair new channels, only the last one will be
covered circularly.
Button Instructions
Functions of P1 button
1. Cycle Operation
:
Press P1 button once and every press the motor will run upward → stop → downward circulary.
2. Pairing or Pair Additional Emitter
:
Press P1 button for 2S, motor jog once, release button and make a long noise, motor is
ready for pairing or pair additional emitter.
3. Radio Lock: Press and hold P1 button for 6S, the motor will jog twice, release button and beep twice, the motor enters radio
lock status, the motor won't receive any signal; press P1 button once to disable Radio Lock.
4. Switch Direction: Press and hold P1 button for 10S, the motor will jog 3 times, release button and beep 3 times, the running
direction of the motor has been changed.
5. Reset to Factory Mode: Press and hold P1 button for 14S, the motor will jog 4 times, release button and beep 4 times, the
motor has been reset to factory mode.At this point the motor will go into deep sleep. After entering deep sleep, the motor can't
be controlled. At this time, you need to press P1 button for 2S and then the motor turns to prompt to exit deep sleep.
*
Dial lithium battery switch, 0 is off switch, 1 is turn on switch.
Back
P2
M
P2
Lithium Cell
3V
P2
DD1803
H Single-channel Timer Emitter
UP
LCD display
STOP
DOWN
Channel
selection“-”
(P1-)
Channel
sel”
(P1+)
P2
P1 button
Lithium Battery Switch
LED light
Micro-USB Port
*If within 10S, the motor doesn't receive STOP signal from the any emitter, it will exit the paring mode automatically.
Re-power on after power off, if the motor has saved the emitter, there is no rotation prompt, and the code matching
status is not automatically entered at this time.
1 Pairing
Factory mode
Essential Settings
The steps in factory mode must be completed to ensure proper operation.
Press P1 button for 2S (1 jog ), release button and make a long noise,
Or turn the DIP switch to “0” and then to “1” (
1 jog and make a long
noise
), repower the motor,
within 10S, press STOP for 2S (2 jogs and
3 beeps ), the motor has been paired successfully.
STOP
*The operation is only valid when there is no limits. If the motor has already set the upper and lower limit, then you can
only switch direction by P1 button.
2 Switch Rotating Direction
(Optional)
+
UP
DOWN
If press UP, the motor runs downward, try below to switch direction
Press and hold UP and DOWN buttons simultaneously for 2S, motor
jog once, the direction has been switched successfully.
P1
→
P1