TECHNICAL SPECIFICATION 

Table 1 Shock chiller/freezers 

Data 

Catalogue No 

DM-S-95106 

DM-S-95110 

Type 

P  -  Transverse arrangement of GN 1/1 containers (unit is equipped with 

fixed racking as standard) 

W -  Longitudinal arrangement of GN1/1 containers (unit is equipped with 

fixed racking as standard) 

D  -  Transverse arrangement of GN 1/1 containers (unit is compatible to 

work with DORAM oven) 

Width [mm] 

900 

Depth [mm] 

830 

Height [mm] 

1610 

1860 

Number and type 
containers to put 

6 x GN 1/1 H = 40 mm 

10 x GN 1/1 H=40mm 

GN Container filling 
height 

~ 40 mm 

Productivity [kg/cycle] 

25 

36 

Power supply [V/Hz] 

230 / 50 

Installed power 

1600 

2000 

Refrigerant 

R 404 A 

Air circulation 

Forced (fan-type) 

Controlling 

Digital 

Equipment 

Product probe 

Optional- printer 

 

Summary of Contents for DM-P 95205

Page 1: ...PL DORA METAL Spółka z o o Edition January 2006 SHOCK CHILLER FREEZERS DM S 951xx SHOCK CHILLER DM S 95205 DM S 952xx GB INSTRUCTION MANUAL ...

Page 2: ...ers and shock chillers freezers This note denotes information particularly important for the end user s security and proper use of the appliance The instruction manual should be studied carefully before setting the appliance into motion ...

Page 3: ...LATION 5 PREPARING THE START UP 5 ELECTRIC TERMINAL 6 USE AND OPERATION 6 APPROPRIATE AND SAFE WORK REGULATIONS 7 TRANSPORT 7 TECHNICAL SPECIFICATION 8 Table 1 Shock chiller freezers 8 Table 2 Shock chiller 9 DATA PLATE 10 NOTES 11 ATTENTION CONTROLLER OPERATION AND ELECTRICAL WIRING DIAGRAM IN APPENDIX NO 3a SHOCK CHILLER 3b SHOCK CHILLER FREEZERS ...

Page 4: ...ature of chilled frozen dish optional automatic recognition of probe presence six independent working programs for chillers soft chill without hold from 700 C to 30 C in 90 minutes soft chill with hold in 30 C blast freeze without hold from 700 C to 30 C in 90 minutes blast freeze with hold in 30 C hold function cooler defrost six independent working programs for chillers freezers soft chill witho...

Page 5: ...ng technology enables to assure HACCP quality standards COOLING SYSTEM OPERATION In the appliance there is a one step compressing cooling circulation The cooling system is filled with an ecological refrigerant R404A the date on the data plate The element which expands is a thermostatic expansion valve INTERIOR TEMPERATURE REGULATION The chamber sensor of the electronic temperature controller is pl...

Page 6: ...by placing the connector in the plug in socket The unit prepared according to the above guidelines is ready to operate Since the appliance could get out of plumb by radius bigger that 30 connecting of the appliance to power supply should be delayed by 3 4 hours Otherwise the condensation unit can be damaged USE AND OPERATION It is recommended to introduce occasional breaks in the appliance operati...

Page 7: ...ny repair can be performed only by an authorised person and in line with the rule saying that used damaged parts can be replaced only with new and identical ones The manufacturer declines all responsibility for all damages arising from improper use of an appliance inconsistent with its purpose It is forbidden to draw night blind in the condensation unit chamber because it can cause improper functi...

Page 8: ... 1 containers unit is equipped with fixed racking as standard D Transverse arrangement of GN 1 1 containers unit is compatible to work with DORAM oven Width mm 900 Depth mm 830 Height mm 1610 1860 Number and type containers to put 6 x GN 1 1 H 40 mm 10 x GN 1 1 H 40mm GN Container filling height 40 mm Productivity kg cycle 25 36 Power supply V Hz 230 50 Installed power 1600 2000 Refrigerant R 404 ...

Page 9: ...1 H 65 5 tac 400 x 600 H 20 6 x GN 1 1 H 40 10 x GN 1 1 H 40 20 x GN 1 1 H 40 20 x GN 1 1 H 40 GN Container filling height 40 mm Productivity kg cycle 15 25 36 72 72 Power supply V Hz 230 50 Installed power 1000 1300 2500 Refrigerant R404A Air circulation Forced fan type Controlling Digital Equipment Product probe Explanations 1 Transverse arrangement of GN 1 1 containers unit is equipped with fix...

Page 10: ...Rated voltage Current frequency Appliance power Max lighting power Heating units power Factory number Total weight Climate class Compressor type Refrigerant Name of the appliance type Place on mark signature of article Manufacturer information Temperature range Refrigerant weight ...

Page 11: ...PL DORA METAL Spółka z o o Chillers and shock chillers freezers 11 NOTES ...

Page 12: ...5 25 15 http www dora metal pl e mail info dora metal pl serwis dora metal pl The information herein can be changed by DORA METAL without notifying the user No part hereof can be copied or spread in any form or by any means without prior consent of DORA METAL Copyright DORA METAL Sp z o o 2006 All rights reserved ...