background image

INTERCHANGEABLE DOOR HANDING

WRENCH

FOREARM

STUD

    30°

APPROX

    30°

PRELOAD

MAIN ARM

HOLD OPEN CONTROL

FOR 441H ONLY 

SHAFT

SCREW

CLOSING SPEED

     VALVE

LATCHING

SPEED

VALVE

BACKCHECK

   VALVE

INSERT

COVER

INSTALLATION SEQUENCE

LEFT HAND DOOR SHOWN - RIGHT HAND DOOR IS OPPOSITE

IMPROPER INSTALLATION OR REGULATION

MAY RESULT IN PERSONAL INJURY OR 

PROPERTY DAMAGE. FOLLOW ALL 

INSTRUCTIONS CAREFULLY.

CAUTION

441C/441H/441S Series

BRACKET

FILLER PLUG

For Heavy Duty Arm w/ STOP (441C), w/ STOP and Hold Open (441H), w/ Spring Stop (441S)

SPRING STOP

FOR 441S 

DEAD-STOP

FOR 441C 

AND 441H

Left Hand

Right Hand

DOOR HANDING

Outside

(Pull Side)

Outside

(Pull Side)

Inside

(Push Side)

Inside

(Push Side)

GENERAL NOTES

1. Door must be hung on ball bearing or anti-friction hinges.

2. Door and frame must be properly reinforced at the door closer and arm mounting areas.

3. For non-labelled wood doors pre-drill and use wood screws.

4. For steel reinforced hollow metal doors, drill and tap for the appropriate machine screws.

5. For non-reinforced hollow metal doors and labeled wood doors, drill and use sex-nut bolts.

6. For steel frames drill and tap for the appropriate machine screws.

7. For optional drop plates installation see separate installation instructions.

8. Door closer should not be installed on an exterior side of a door or door frame surface. 

9. Hold open arms should NOT be installed on fire doors

1. Determine door handing (refer above) and position door closer with spring tube end located away from 

the hinges centerline.

2. Before installing the door holder ensure that the backcheck is not engaged. Turn backcheck 

valve-screw counter-clockwise. Also, ensure that the valve at the back of the door closer is completely 

screwed-in.

3.  Select the desired degree of opening as indicated on page 2 and use the appropriate position of door 

closer and parallel arm bracket with respect to the hinge centerline. Mark the parallel arm bracket 

mounting holes on the frame door stop soffit using the actual parallel bracket at the selected location 

(as illustrated on page 2).

4. Mark the door closer mounting holes on the door at selected location.

  a. For prepped (reinforced) hollow metal doors, drill and tap for ¼-20 UNC and attach door closer to 

door using provided machine screws.

  b. For non-prepped hollow metal fire rated doors: drill 3/8” (9.5 mm) holes on exterior door surface and 

5/16“ (8 mm) hole on door interior surface and attach door closer to door using through bolt sexnuts 

and machine screws. (Not supplied)

5. For non-rated wood doors pre-drill 3/16” (4.8 mm) and use wood screws. For fire rated wood doors drill 

3/8” (9.5 mm) holes through door and attach door closer to door using through bolt sexnuts and 

machine screws. (Not supplied)

6. Using a wrench on the door closer bottom shaft (refer to illustration below), turn the shaft towards the 

hinge about 30° (for pre-loading) and place main arm on the closer’s top shaft. Insert the main arm 

screw into the top shaft and tighten.

7. Temporarily remove the arm stop from the parallel bracket and disengage the Hold-Open function with 

the Hold-Open control handle (if arm with Hold-Open function is used).

8. Rotate the arm on the closer shaft so that the main arm is approximately parallel to the door and 

ensuring that the arm elbow clears the door surface by about 1/2” to 1” (13mm to 25mm). Verify that 

the parallel arm bracket holes line-up with the marked-up holes. Once the position of the holes has 

been verified, remove the arm with bracket and proceed in preparing the mounting holes as instructed 

in note 9.

9. For prepped frames or metal frames, drill and tap for ¼-20 UNC and use provided machine screws. 

For non-prepped frames or wood frames, pre-drill and install provided #14 wood screws.

10. To provide additional stiffness to the parallel bracket mounting, install an additional mounting screw on 

the parallel bracket using the spacer block between the door frame jamb ceiling face and the parallel 

bracket.

11. Install the arm solid stop  or the spring stop on the parallel arm bracket and verify that the door opens 

to the approximate desired opening angle. Install supplied filler plug on the unused stop position hole.

12. Door Closer Control Adjustment:

  a. Adjust the closer closing speeds using the closer regulating valves as required. Turn valves 

clockwise for a slower closing speed and counter-clockwise for a faster closing speed. A normal 

closing time from 90° open position to door stop positions is 5-7 seconds, evenly divided between 

door closing moving speed and latch speed.

  b. Adjust spring power if required, depending on door size and weight.

  c. Adjust the backcheck to slow down the door before the dead-stop. Note that the backcheck is used 

only to provide damping and prevent the door from opening too fast. Does not replace door stop.

  d. For arms with Hold-Open function, engage the spring loaded detente by turning the control handle 

90° as shown.

13. To install the door closer cover, first place insert in the appropriate cutout, place shaft insert over the 

lower shaft, then install cover and secure with supplied mounting screws.

5/32” OR 4 mm

Allen key

441C/441H/441S-INST 2022-04

PAGE 1

SPRING TUBE

SCREW